Stove Dimensions
Floor Protection
This unit must be installed with floor protection of a non-combustible protective floor pad of a minimum 3/8”
(10mm) thickness material or a masonry hearth. Follow the below diagram for sizing.
Min. Installation Clearance to Combustibles
Minimum clearances to combustible surfaces must be maintained. See diagrams below and on pages 11-16.
Keep all combustibles outside of these clearance areas. INSTALL VENTING AT CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER. Clearances may only be reduced by means approved by the regulatory
authority.
Alcove Clearances
Maximum Alcove depth: 36”. Minimum Alcove height: 57.5” Minimum Alcove Width: 41”