Page
6
of
30
E.
Controls & Plumbing Connections
The GT boiler uses a hot water thermostat (aquastat) with a sensor that is inserted into a brass
drywell for sensing the water temperature of the unit. When the temperature falls below the
differential setting on the aquastat, the blower turns on and the damper actuator opens, feeding
oxygen to burn wood in the firebox, heating the water jacket and remaining on until the water
temperature in the boiler reaches the set point of the aquastat.
The temperature is permanently set for 170F with a differential of 5 degrees for optimum operation
and performance and also provides for a long enough cycle time to burn off any creosote that
accumulated during idling.
There is also a safety thermal snap disc at the water output port that will shut off the boiler if output
temperature reaches 180F to ensure it never exceeds a safety standard of 204F as stored heat in
the refractory will continue to heat the water after shutdown. Differential is 20 degrees.
Boiler shown is set up as a single-zone.
Porting for a 2
nd
zone is provided.
(Additional pumps & valves are available from your
dealer and can be ordered installed as well.)
1. Lower outlet for battery charger and control
plug that feeds power to the upper outlet
and controls
2. Upper outlet for circulation pump(s),
convenience load
3. Rear switch (front switch also shuts down
blower & closes firebox air damper)
4. Aqua-stat sensor for controlling blower and
firebox air damper
5. Blower to feed oxygen to fire
6. Firebox air damper actuator
7. Output ports
Please note! The pump that comes
with the boiler may not be the correct size for the
installation. Please consult your dealer for sizing as
water flow is essential to the proper & efficient
operation of the installation.
8. Rear access cover for refractory and rear
heat exchanger tubes
9. Output Temperature gauge
10. Drain Valve
11. Return ports (Use an additional valve here
for ease of servicing, not included.)
12. Rear access cover for upper and rear heat
exchanger tubes
13. Aquastat sensor