Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1
Maximum temperature -
Set Temperature
– adjust the upper limit of the range for the boiler’s
temperature
Safety Setup
– A high temperature sensor pt100 monitors the temperature of the exhaust gases. The
parameter
Warn
sets the value (in Celsius), above which the controller displays a warning message
Cleanup. The parameter
Alarm
sets the value (in Celsius), above which the controller displays a
message TE Alarm and turns off the burner, because the temperature of the exhaust gases is too high.
In both cases the boiler needs to be cleaned up. If the burner doesn't have a high temperature sensor
pt100, this function could be disabled by removing the check sign on the row
Active
.
The following screens are available only if the burner is in Standby mode!!!
Test Fan Speed
– test setting for fan's speed. The power of the air fan can be increased or decreased
in percents by
▲
and
▼
buttons.
This function has limited active time and turns off automatically.
Test the Exhaust fan –
Test EFan Speed
–
test setting for fan's speed. The power of the exhaust
fan can be increased or decreased in percents by
▲
and
▼
buttons.
This function has limited active
time and turns off automatically.
User Manual / version 2.6
http://www.naturela-bg.com/en/