SPECIFICATIONS

Nominal input voltage ..................................................................................12.8-13.2 VDC
Nominal output voltage ................................................................................115±10% VAC
Output frequency ...................................................................................................60±3 Hz
Operating input voltage ................................................................................10.0-15.0 VDC
Continuous output power .............................................................................. Up to 2000 W
Surge output power

 

................................................................................................ 4000 W

Waveform
Efficiency (typical)

 ............................................................................................. Modified sine wave

 

....................................................................................................... 86%

Typical No Load Current (at nominal input voltage)  ..............................................0.7 ADC
Input overvoltage shutdown ..........................................................................15.5±0.5 VDC
Input undervoltage alarm ..............................................................................10.5±0.5 VDC
Input low voltage shutdown...........................................................................10.0±0.5 VDC
Output power overload shutdown level ...........................................................2400±400 W
Input fuse  

.................................................................................................................8x30 A

AC receptacles..............................................................................Three, NEMA 5-15 USA

USB port .......................................................................................................... One, 5V 2A
Battery cables

 

.........................................................................................

 

5

AWG, 

2

×39.3 in

Ground wire ...........................................................................................1

5

AWG, 1×39.3 in

Page 1

2

  of  1

4

Содержание 37002

Страница 1: ...AVE THESE INSTRUCTIONS WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Item 37002 ...

Страница 2: ...v Page 2 of 14 T an you for c oosin a Nature Po er Pro uct This product is designed for certain applications only Distributor cannot be responsible for issues arising from modification We strongly recommend this product not be modified and or used for any application other than that for which it was designed If you have a question relative to a particular application o not use the product until yo...

Страница 3: ...unplug unit from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk 7 For the most effective use place the power inverter on a flat surface 8 Do not place the inverter on or near heating vents radiators or other sources 9 Do not place the inverter in direct sunlight The ideal air temperature for operation is between 50 and 80 F 10 Only connect the p...

Страница 4: ...t your inverter only to a 12 volt power supply To avoid electrical shock it is necessary to ground the inverter as well as the device powering it The inverter should be grounded using a 15 AWG copper wire included NOTE Do not turn on the inverter or the power source until the inverter and the power source are grounded TO GROUND THE INVERTER 1 Turn off and disconnect the inverter 2 Locate the chass...

Страница 5: ...G INVERTER CABLES TO THE INVERTER 1 Locate the Positive and Negative terminals on the inverter 2 From the POSITIVE RED and the NEGATIVE BLACK terminals remove 3 Place the POSITIVE RED ring connector onto the POSITIVE RED inverter terminal Place the NEGATIVE BLACK ring connector onto the NEGATIVE BLACK inverter terminal 4 top of each ring connector Put a nut over these and tighten NOTE Please use t...

Страница 6: ...Page of 14 OUTPUT POWER INDICATE LIGHT ...

Страница 7: ...ritical condition REMOTE When you set the switch to the REMOTE II position the Inverter provides AC power to connected equipment by converting DC power from your vehicle s battery The green LED will illuminate to indicate it is working You can then power the inverter ON OFF from a remote location via the included remote This remote switch can be mounted in the vehicle or a permanent mount applicat...

Страница 8: ...he inverter is running only light loads it is advisable to recharge before the inverter low voltage shutdown point is reached IMPORTANT The inverter draws low amperage from the battery with the main ON OFF switch turned on and no load connected To prevent battery discharge turn the inverter off when you are not using it indicating the Inverter is receiving power Switch the Inverter s ON OFF REMOTE...

Страница 9: ...e or replace the battery 2 When the power input from the vehicle s battery exceeds 16 volts high voltage protection occurs The continuous load demand from the equipment or device being operated exceeds the continuous load rating of the inverter Use a higher capacity inverter or lower rated device 4 The thermal resistor exceeds 80 C 176 F Allow the inverter to cool Do not block the cooling slots or...

Страница 10: ...NS 1 Before each use ensure that all of the inverter s components are in place and in good working condition 2 After use and before performing maintenance unplug and disconnect the inverter 3 Use a clean dry cloth to wipe external surfaces of the inverter s case 4 Servicing does not require opening the unit as there are no user serviceable parts All servicing should be performed 5 Store inside in ...

Страница 11: ... The equipment being operated is drawing too much power The inverter is too hot thermal shutdown Recharge or replace the battery Use a higher capacity inverter or decrease the load or device on the inverter Allow inverter to cool Check for adequate ventilation Reduce the load on the inverter to the rated continuous power output Device does not operate properly to the inverter The inverter may not ...

Страница 12: ...veform Efficiency typical Modified sine wave 86 Typical No Load Current at nominal input voltage 0 7 ADC Input overvoltage shutdown 15 5 0 5 VDC Input undervoltage alarm 10 5 0 5 VDC Input low voltage shutdown 10 0 0 5 VDC Output power overload shutdown level 2400 400 W Input fuse 8x30 A AC receptacles Three NEMA 5 15 USA USB port One 5V 2A Battery cables 5AWG 2 39 3 in Ground wire 15AWG 1 39 3 in...

Страница 13: ... Number must be issued by Nature Power and the defective part or unit should be returned to the authorized location at the purchasers expense A dated proof of purchase is required to receive warranty service Once received at authorized location and defect proves to be the result of defective material and workmanship the defective part or unit will be replaced at warrantors option and returned to t...

Страница 14: ...Please contact NaturePower Productsto acquire more information 1 800 588 0590 info naturepowerproducts com www naturepowerproducts com Made in Taiwan Page 14 of 14 ...

Отзывы: