41
accessible and located within site and
arm’s reach of the furnace. Connect
from the electrical disconnect to the
junction box on the left side of the
furnace, inside the blower compartment.
For the proper connection, refer to the
appropriate wiring diagram located on
the inside cover of the furnace control
box and in these instructions.
NOTE: UPFLOW MODELS ONLY
The electrical junction box may be
moved to the right side if necessary. A
knockout is provided. Seal the opposite
hole with plug provided.
NOTE:
L1 (hot) and N (neutral) polarity
must be observed when making field
connections to the furnace. The ignition
control may not sense flame if L1 and
Neutral are reversed. When L1 and
Neutral are reversed, a diagnostic code
of 6 blinks followed by a pause and 6
FIGURE 40
LINE VOLTAGE CONNECTIONS
UT ELECTRONIC CONTROLS 1095-206 CONTROL BOARD
ELECTRICAL WIRING
TURN OFF ELECTRIC POWER AT
FUSE BOX OR SERVICE PANEL
BEFORE MAKING ANY ELECTRICAL
CONNECTIONS. FAILURE TO DO SO
CAN CAUSE ELECTRICAL SHOCK
RESULTING IN PERSONAL INJURY
OR DEATH.
NOTE:
Electric to furnace must be
supplied by commercial utility. Proper
voltage is 110-125 volts.
THE CABINET MUST HAVE AN
UNINTERRUPTED GROUND
ACCORDING TO THE LATEST
EDITION OF THE NATIONAL
ELECTRICAL CODE, ANSI/ NFPA70-
OR IN CANADA, THE CANADIAN
ELECTRICAL CODE, CSA-C221 OR
LOCAL CODES THAT APPLY. DO
NOT USE GAS PIPING AS AN
ELECTRICAL GROUND. A GROUND
SCREW IS PROVIDED IN THE
JUNCTION BOX. FAILURE TO DO SO
CAN CAUSE ELECTRICAL SHOCK
RESULTING IN PERSONAL INJURY
OR DEATH.
THIS FURNACE IS EQUIPPED WITH A
BLOWER DOOR SAFETY SWITCH.
DO NOT DISABLE THIS SWITCH.
FAILURE TO FOLLOW THIS
WARNING CAN RESULT IN
ELECTRICAL SHOCK, PERSONAL
INJURY OR DEATH.
IMPORTANT:
The furnace must be
installed so that the electrical
components are protected from water
(condensate).
Before proceeding with the electrical
connections, be certain that the voltage,
frequency and phase corresponds to
that specified on the furnace rating
plate. For single furnace application,
maximum over-current protection is 15
amperes.
Use a separate fused branch electrical
circuit containing a properly sized fuse
or circuit breaker. Route this circuit
directly from the main switch box to an
electrical disconnect that is readily
!
WARNING
!
WARNING
!
WARNING
blinks will be displayed on the control
board “Status” L.E.D. See Figure 40.
Make all electrical connections in
accordance with the latest edition of
the National Electrical Code
ANSI/NFPA70 and local codes having
jurisdiction.
These may be obtained from:
National Electric Code
National Fire Protection
Association, Inc.
Batterymarch Park
Quincy, MA 02269
CSA Standards
CSA - International
178 Rexdale Blvd.
Etobicoke (Toronto), Ontario
Canada M9W, 1R3