background image

Safety

www.nationalequipment.com

Phone: 763-315-5300

5

GENERAL RULES FOR SAFE OPERATION

READ AND SAVE ALL INSTRUCTIONS FOR FUTURE USE:

 Before use, be sure everyone operating this equipment reads and 

understands this manual as well as any labels packaged with or attached to the tool.

1. KNOW 

YOUR 

EQUIPMENT:

 Read this manual carefully to learn equipment applications and limitations as well as potential hazards 

associated with this type of equipment.

2. GROUND 

YOUR 

TOOL:

 See Grounding (See Page 7).

3.  AVOID DANGEROUS ENVIRONMENTS:

 Do not use in rain, damp or wet locations, or in the presence of explosive atmospheres 

(gaseous fumes, dust or fl ammable materials). Remove materials or debris that may be ignited by sparks.

4.  KEEP WORK AREA CLEAN AND WELL LIT:

 Cluttered, dark work areas invite accidents.

5.  DO NOT USE ON STEPS.

6. DRESS 

PROPERLY:

 Do not wear loose clothing. 

7.  USE SAFETY EQUIPMENT:

 Everyone in the work area should wear safety goggles or glasses complying with current safety stan-

dards. Wear hearing protection during extended use and a dust mask for dusty operations. 

8. KEEP 

BYSTANDERS 

AWAY:

 Children and bystanders should be kept at a safe distance from the work area to avoid distracting the 

operator and contacting the tool or extension cord. Operator should be aware of who is around them and their proximity.

9.  PROTECT OTHERS IN THE WORK AREA:

 Provide barriers or shields as needed to protect others from debris. 

10. USE PROPER ACCESSORIES: 

Using accessories that are not recommended may be hazardous. Be sure accessories are prop-

erly installed and maintained.

11.  CHECK FOR DAMAGED PARTS:

 Inspect guards and other parts before use. Check for misalignment, binding of moving parts, 

improper mounting, broken parts and any other conditions that may affect operation. If abnormal noise or vibration occurs, turn the tool 
off immediately and have the problem corrected before further use. Do not use damaged equipment. Tag damaged tools “DO NOT USE” 
until repaired. A guard or other damaged parts should be properly repaired or replaced. For all repairs, insist on only identical National 
replacement parts.

12.  REMOVE ALL ADJUSTING KEYS AND WRENCHES:

 Make a habit of checking that the adjusting keys, wrenches, etc. are 

removed from the tool before turning it on.

13. GUARD AGAINST ELECTRIC SHOCK:

 Prevent body contact with grounded surfaces such as pipes, radiators, ranges and 

refrigerators. Before use always check the work area for hidden wires or pipes.  Use a Ground Fault Circuit Interrupter (GFCI) to reduce 
shock hazards.

14. AVOID ACCIDENTAL STARTING:

 Be sure equipment is turned off before plugging it in. Do not use a tool if the power switch does 

not turn the tool on and off.

15. DO NOT ABUSE CORD:

 Never unplug by pulling the cord from the outlet. Pull plug rather than cord to reduce the risk of damage. 

Keep the cord away from heat, oil, sharp objects, cutting edges and moving parts.

16. STAY ALERT:

 Watch what you are doing, and use common sense. Do not use when you are tired, distracted or under the infl uence of 

drugs, alcohol or any medication causing decreased control.

17. STARTING MACHINE:

 On/off switch must be in off position before connecting to power source. 

18.  DO NOT DEFEAT OR ALTER A SWITCH OR SAFETY DEVICE 

19. UNPLUG EQUIPMENT:

 When it is not in use, unplug tool before changing accessories or performing recommended maintenance.

20. MAINTAIN EQUIPMENT CAREFULLY: 

Keep handles dry, clean and free from oil and grease. Periodically inspect tool cords and 

extension cords for damage. Have damaged parts repaired or replaced.

Содержание 3402

Страница 1: ...HEAVY DUTY DUST COLLECTOR INSTRUCTION MANUAL Caution Read Manual Before Operating Machine 043014 Rev A...

Страница 2: ......

Страница 3: ...Maintenance 11 14 Standard Filter Inspection 11 Standard Filter Removal 11 Standard Filter Installation 12 HEPA Filter Replacement Procedure 13 Motor Brushes Inspection 14 Troubleshooting Guide 15 Par...

Страница 4: ...high cfm for fast pick up of airbone particles 2 Inlet 2 inlet attaches 25 crushproof vacuum hose Heavy Duty Locking Casters allows maneuverability on any sur face with self locking casters Steel Han...

Страница 5: ...binding of moving parts improper mounting broken parts and any other conditions that may affect operation If abnormal noise or vibration occurs turn the tool off immediately and have the problem corr...

Страница 6: ...RY AILMENTS USE APPROVED NIOSH OR OSHA RESPIRATOR SAFETY GLASSES OR FACE SHIELDS GLOVES AND PROTECTIVE CLOTHING PROVIDE ADEQUATE VENTILATION TO ELIMINATE DUST OR TO MAINTAIN DUST LEVEL BELOW THE THRES...

Страница 7: ...to an electrically live terminal Your tool must be plugged into an appropriate outlet properly installed and grounded in accordance with all codes and ordinances The plug and outlet should look like t...

Страница 8: ...nto outlet Do not remove bend or modify any metal prongs or pins of cord Do not use excessive force to make connections Do not connect a three prong plug to a two hole cord Avoid overheating Uncoil co...

Страница 9: ...the dust container is empty and that no one else is standing under the lifted machine Risk of per sonal injury and material damage CAUTION MACHINE IS DESIGNED FOR INTERMITTENT USE I E NOT MORE THEN 2...

Страница 10: ...rce as indicated on the machine s serial tag 3 Start the machine by pushing the power switches on the motors to the ON posi tion one at a time See Figure C 4 Turn the machine off by pushing the power...

Страница 11: ...ground wire from the subsequent assembly via the push on terminal 6 Disconnect the three power cord wires from the terminal block on the underside of the motor deck Figure G 7 Remove the motor deck 8...

Страница 12: ...er housing spacer assembly via push on terminal 6 Seat the HEPA adapter assembly and housing spacer if so equipped on the pre ceding housing component oriented as removed make sure to connect the comp...

Страница 13: ...ring flat gasket material on the HEPAfilter frame if not already done so to cushion the HEPA filter brackets 13 Replace the HEPA filter brackets and ring to tab terminal then thread the locking nuts o...

Страница 14: ...p via the built in hooks on both sides of each motor brush TIP Dislodge one side of a cap first then the other 8 Remove the motor brush retainers via the 2 phillips screws per brush 9 Remove each of t...

Страница 15: ...to place the unit under vacuum pressure then inspect for air leaks Material in exaust or on top side of filter Poor filter seal or torn filter Follow Filter Inspection Procedure See Page 11 Unusual or...

Страница 16: ...asket for Motor Head 1 9 34817A M6 Blind PEM 4 10 20020 Hold Down Bracket for WS Motor 2 11 26603 Knob for Motor Hold Down M6 2 12 27003 8 x 2 Phil Pan Head Zinc 6 13 8021 Protection Scree Motor Head...

Страница 17: ...rene Sponge Gasket 2 7 27001 Motor Head Aluminum 2 8 27004 Gasket for Motor Head 2 9 34817A M6 Blind PEM 6 10 90223WNS Motor Deck Red WNS 2 Motor 1 11 20020 Hold Down Bracket For WS Motor 4 12 26603 K...

Страница 18: ...nationalequipment com 18 1 27017 Switch Toggle WS 1000 1200 1 2 25211 Male IEC Plug 1 3 34905A Ground Wire From Plug to Motor 2 4 2005531 Power Cord 12 3 SJO w Molded 110V Plug 1 5 25209 Female IEC Pl...

Страница 19: ...otor 4 4 34993 Ground Cable 16 Gauge Green 2 5 34960 PG 09 Cable Grip 2 6 25048 8 32x3 4 Phillips Flat Head 2 7 25049 8 32 Hex Nut 2 8 34961 Strain Relief 90 Deg 1 2 NPT 1 9 2005531 Power Cable 1 10 2...

Страница 20: ...Parts List and Diagrams Fax 763 535 8255 info nationalequipment com 20...

Страница 21: ...Filter 1 25 34998 Ground Connection For Bolt 2 26 34876 M6 Lock Nut Zinc 1 27 34871 Plastic Plug 4 5 13 4 28 34815 M6 x 30 Flat Socket Cap Screw 4 PART DESCRIPTION QTY PART DESCRIPTION QTY 1 34823 Ho...

Страница 22: ...Foot WS DS1 1 5 32903 M6x1 0x20 Hex Cap Screw Zinc 4 6 34947 HEPA Adapter Plate DS1 1 7 20039 M6 Split Lock Washer 4 8 34949 HEPA Hold Down Bracket WS 4 9 32835 Housing Spacer Large Black 1 10 34820 H...

Страница 23: ...8 25037 M8 Washer HEPA Machines have 5 6 9 25054 M8 x 25 Hex Bolt 4 10 25085 Dual Casters Fixed 75MM w Stud 2 11 20070 Gasket Dust Pan Lower Housing 20x15MM 1 12 34813 Dust Pan 35LTR Red 1 13 25038 M8...

Страница 24: ...M6 Flat Washer 4 6 20027 Flat Steel Pivot 2 7 34853 Dust Pan Lever Bearing 2 8 34852 Dust Pan Tension Lever 2 9 34922 Pin D 6X 19MM 2 10 20044 M8 Hex Nut 8 4 11 34882 M8 Flat Washer 6 12 25053 M8 x 3...

Страница 25: ...RIPTION QTY 1 30007 Inlet 70MM Aluminum 1 2 34821 Gasket 70MM Inlet 1 3 30008 Deflector 70MM Aluminum 1 4 32866 M5 8x30 Socket Cap Allen Head 3 5 32863 M5 8x20 Socket Cap Screw 1 6 32867 M5 EXT Tooth...

Страница 26: ......

Страница 27: ...nd shall be the sole and exclusive remedy available to the purchaser Correction of defects in the manner and for the period of time described herein shall constitute complete fulfillment of all liabil...

Страница 28: ...LOORING EQUIPMENT 9250 Xylon Avenue N Minneapolis MN 55445 U S A Toll free 800 245 0267 Phone 763 315 5300 Fax 800 648 7124 Fax 763 535 8255 Web Site www nationalequipment com E Mail info nationalequi...