PRODUCT FICHE 

For Residential Ventilation Units  (Complying Commission Delegated Regulation (EU)                                             

No 1254/2014) 

 

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 

Name:

  

Monsoon

 

Monsoon

 

Model

 

ID

 

(Stock

 

Ref.)

 

:

 

MON

MEVH

 

MON

MEVH

 ‐ 

LDC

 

SEC

 

Class

 

E

 

C

 

SEC

 

Value

 

('Average')

 

16.52

 

24.69

 

SEC

 

Value

 

('Warm')

 

4.51

 

9.18

 

SEC

 

Value

 

('Cold')

 

37.49

 

51.75

 

Label

 

Required?

 

(Yes/No=Out

 

of

 

scope)

 

Yes

 

Yes

 

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

 

RVU/UVU

 

RVU/UVU

 

Speed

 

Drive

 

Multi

Speed

 

Multi

Speed

 

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

 

None

  

None

  

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

 

N/A

  

N/A

  

Max.

 

Flow

 

Rate

 

(m3/h)

 

350.28

 

350.28

 

Max.

 

Power

 

Input

 

(W):

 

(@Max.Flow

 

Rate)

 

81.00

 

81.00

 

LWA:

 

Sound

 

Power

 

Level

 

(dB)

 

51.53

 

51.53

 

Ref.

 

Flow

 

Rate

 

(m3/s)

 

0.06811

 

0.07

 

Ref.

 

Pressure

 

Diff.

 

(Pa)

 

185.00

 

185.00

 

SPI

 

[W/(m3/h)]

 

0.22

 

0.22

 

Control

 

Factor

 

&

 

Control

 

Typology:

 

(CTRL/

 

Typology)

 

  

0.00

 

Control

 

Factor;

 

CTRL

 

0.85

 

0.65

 

Control

 

Typology

 

Central

 

Demand

 

Control

 

Local

 

Demand

 

Control

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                                                    

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

 

<5%

 

Internal,

 

<5%

 

External

 

<5%

 

Internal,

 

<5%

 

External

 

Mixing

 

Rate

 

of

 

Non

Ducted

 

BVUs

 

not

 

intended

 

to

 

be

 

equipped

 

with

 

one

 

duct

 

connection

 

on

 

either

 

supply

 

or

 

extract

 

air

 

side;

 

N/A

 

N/A

 

Position

 

and

 

description

 

of

 

visual

 

filter

 

warning

 

for

 

RVUs

 

intended

 

for

 

use

 

with

 

filters,

 

including

 

text

 

pointing

 

out

 

the

 

importance

 

of

 

regular

 

filter

 

changes

 

for

 

performance

 

and

 

energy

 

efficiency

 

of

 

the

 

unit

 

N/A

 

N/A

 

For

 

UVUs

 

(Instructions

 

Install

 

Regulated

 

Supply/Extract

 

Grilles

 

Façade)

 

In

 

F&W

 

In

 

F&W

 

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

 

www.nationalventilation.com

 

www.nationalventilation.com

 

Sensitivity

 

p.

 

Var20/

20

 

Pa:

 

(for

 

Non

Ducted

 

VUs)

 

N/A

 

N/A

 

Air

 

Tightness

ID/OD

(m3/h)

 

(for

 

Non

Ducted

 

VUs)

 

N/A

 

N/A

 

Annual

 

Electricity

 

Consumption:

 

AEC

 

(kWh/a)

 

2.16

 

1.45

 

Annual

 

Heating

 

Saved:

 

AHS

 

(kWh/a)

 

  

0.00

 

AHS:

 

Average

 

21.93

 

28.30

 

AHS:

 

Warm

 

9.92

 

12.80

 

AHS:

 

Cold

 

42.90

 

55.36

 

Содержание Monsoon MON-MEVH

Страница 1: ...MON MEVH PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Installation and Wiring Instructions 220 240V 50Hz IP22...

Страница 2: ...e isolator switch having a contact separation of at least 3mm The fuse rating should be 3A C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D It is recommended...

Страница 3: ...with reduced physical sensory and mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and unde...

Страница 4: ...d point potentiometer setting of 75 RH Once a humidity level is dedicated above the set point value the MON MEVH will initiate a fixed airflow boost cycle depending on the initial speed setting of uni...

Страница 5: ...ke use a suitable adaptor attached using the 4 holes provided 3 Ducting passing through an unheated roof void should be insulated Ducting runs should be as straight as possible and intake ducting shou...

Страница 6: ...lly to an increase in RH above the set point value and the manner in which this triggers will increase airflow depending on the original speed setting as follows Low Speed Setting If high humidity is...

Страница 7: ...Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External 5 Internal 5 Exte...

Страница 8: ...National Ventilation Stathe Road Burrowbridge Somerset TA7 0RY 475921A 0217 Contact Information Website www nationalventilation co uk email info nvagroup co uk Sales and technical hotline 01823 69029...

Отзывы: