National Vacuum Equipment 887 Challenger Series Скачать руководство пользователя страница 29

887 Challenger Series  |  

29

www.natvac.com  |  800.253.5500

NVE 887 Challenger - Fan Cooled Parts Breakdown 

ITEM

QTY

PART NUMBER

DESCRIPTION

1

1

120-001-006

887 HOUSING, MACHINED

2

1

120-005-008

887 ROTOR ASSEMBLY

3

2

120-004-001

GASKET 887 ENDPLATE

4

1

120-003-009

887 ENDPLATE (CW NON DRIVE, CCW DRIVE) MACHINED

5

1

120-003-008

887 ENDPLATE (CW DRIVE, CCW NONDRIVE) MACHINED

6

2

120-009-004

SEAL SLEEVE 887

8

1

120-019-001

BEARING BALL 887 DRIVE END

9

1

120-019-002

BEARING ROLLER 887 NON DRIVE END

10

2

120-406-002

WASHER WAVE 887

11

2

120-055-001

GASKET 887 BEARING COVER

12

1

120-054-006

COVER BEARINGS DRIVE END 887

14

1

120-054-005

COVER BEARINGS NON DRIVE END 887

17

1

120-097-002

GASKET 887 BALLAST MANIFOLD

18

1

120-090-009

BALLAST MANIFOLD 887

21

6

120-059

PLUG BRASS HED HEAD 0.25”NPT

23

2

120-039-004

GASKET 887 INTAKE/EXHAUST

24

1

120-320-009

HOUSING FILTER 887

25

1

120-039-005

GASKET 887 FILTER HOUSING/4-WAY

26

1

120-316-001

FILTER PILOT 887

27

1

120-064-030

O-RING SQUARE VITON 436

30

2

120-045-005

887 EXHAUST CHECK WAVE SPRING

31

1

120-041-004

CHECK VALVE 887

32

1

120-067-009

HOUSING 4-WAY VALVE 887

35

1

123-000-003

OIL PUMP 4 PORT BIDIRECTIONAL

36

1

320-LF8

DRIVE TAB

37

1

320-R31

GASKET, OIL PUMP

40

1

120-062-009

PLUG 887 MACHINED

41

1

120-065-009

TOWER 887 MACHINED

43

1

120-045

4-WAY FV SPRING (COMPRESSED)

45

1

412-060-009

HANDLE, 4-WAY TOP ADJ ENCLOSED

49

1

120-060-002

GRIP, HANDLE WITH LOGO

50

1

120-314-003

887 INTAKE FILTER ASSEMBLY

51

1

120-310-001

COVER, FILTER 607/866

54

4

120-312-002

KNOB, 5/16-18UNC

56

2

320-408-016

FITTING STR -3 MJIC X 1/8 MNPT

58

6

123-408-014

BANJO BOLT 1/8” BSPP

59

12

123-013-001

WASHER 3/8” SEALING NBR

61

1

120-074-002

FAN SHROUD 887 MACHINED

66

1

120-071-003

TIN SUPPORT 887

67

3

320-409-005

P-CLIP, 1/4”HOSE W/3/8”HOLE, VINYL CUSHION

70

1

120-070-001

TIN LOWER ROLLED 887

71

1

120-071-001

TIN UPPER ROLLED 887

72

1

120-006

KEY, 3/8” X 3/8” X 2

73

1

120-076

KEY, 3/8” X 3/8” X 1”

74

1

120-084-003

FAN ASSEMBLY CW 887

75

1

120-073-E

E-COAT FAN GUARD

78

1

120-079-005

GUARD, OIL PUMP 607

84

1

120-068

O-RING, 2-252 VITON

85

2

120-064-017

O-RING, 2-216 VITON

86

1

120-064-004

O-RING, 2-265 VITON

87

1

120-645-001

LOCK NUT 887

89

7

120-007-887

VANE 887

95

2

120-053-506

SEAL, 45 X 62 X 8 VITON

Содержание 887 Challenger Series

Страница 1: ...NationalVacuumEquipment MADE IN THE USA Visit our web site to download pump setup guides brochures and other technical information Owner s Manual 887 Challenger Series Rotary Vane Vacuum Pumps...

Страница 2: ...sion 1 Release February 2017 No part of this manual may be reproduced without the written permission of National Vacuum Equipment Inc 887 CHALLENGER Owner s Record Date of Purchase ___________________...

Страница 3: ...w natvac com 800 253 5500 Counter Clockwise Rotation Clockwise Rotation IMPORTANT INFORMATION FOR INSTALLING PUMP 887 CHALLENGER SERIES PUMPS AERIAL VIEW SHADED AREAS MUST BE KEPT CLEAR FOR SERVICING...

Страница 4: ...Oil Settings 12 Operating Instructions 14 Normal Operation 14 Recommended Lubricant 15 Ballast Valve System 15 Ballast Valve Troubleshooting 16 Adjusting Ballast Valve Opening Level 16 Ballast Valve R...

Страница 5: ...a timely basis We are a one stop shop for manufacturers and distributors of vacuum equipment Our History National Vacuum Equipment Inc was founded in 1980 by Bruce Luoma The Company started as a reta...

Страница 6: ...1 year period shall begin the day the product is shipped from our warehouse unless we are provided with an authentic copy of the original resale invoice in which case the one 1 year period shall begi...

Страница 7: ...the National Vacuum Equipment Inc Manufacturer s Warranty 11 Final assemblers responsibility NVE goes to great lengths to insure the quality and proper functionality of the products it supplies Many...

Страница 8: ...od Customer must receive a return goods authorization RGA before returning product All serial numbered products must retain the NVE serial number tag to be qualified for warranty Product must be retur...

Страница 9: ...tions are Oil Field Septic Restaurant Grease Industrial Waste Pump Specifications _____________________________________________ 887 Challenger HP Calculated Flow Data 887 CHALLENGER Model Specific Inf...

Страница 10: ...re trap This will allow the vacuum relief valve to relieve vacuum to the pump even when the moisture trap shut off ball activates shutting off flow of air to the vacuum pump Vacuum relief setting will...

Страница 11: ...initial torque damage Direction of Rotation ___________________________________________ The direction of rotation and RPM are marked on the front of the pump The direction of rotation required by you...

Страница 12: ...Jam Nut 4 Tighten adjustment screw CW until it seats on the cam Do not force Seated Against Flat of Cam 5 Back the screw off the desired amount of turns CCW 887 4 75 turns Tip More turns out equals le...

Страница 13: ...atvac com 800 253 5500 Adjusting Factory Oil Settings Continued Turns From Bottom Ounces Per Hour 7 5 6 7 25 7 7 8 6 75 9 6 5 10 6 11 5 5 12 5 13 4 75 14 4 5 15 4 25 16 NVE 4 Port Oil Pump Adjustment...

Страница 14: ...900 RPM where a higher RPM will result in increased air flow over 500 CFM at 1 200 RPM but a more limited working vacuum level approximately 23 hg at 1 200 RPM RPM should be established based on the n...

Страница 15: ...ballast air cooling system It works by allowing cooling air to enter the pump at higher vacuum levels just prior to the exhaust port This allows the pump to dissipate the heat produced by friction The...

Страница 16: ...adjustment screw set to open too low see next section Debris caught in ballast valve plunger see ballast valve rebuilding section Worn ballast valve plunger pilot see ballast valve rebuilding section...

Страница 17: ...e Without the boss plug vacuum chamber is not sealed thus cracking level may vary slightly adjustment holds accurate replace locking jam nut boss plug and the ballast air filter LOCKING JAM NUT BALLAS...

Страница 18: ...slight spring tension 3 Remove cover carefully spring should stay in cover 4 Remove plunger assembly from ballast valve 5 Remove nut from plunger assembly and disassemble 6 Replace ballast valve diaph...

Страница 19: ...e ballast valve diaphragm and the ballast protective gasket and reassemble plunger assembly 7 Place a small amount of Loctite on threads and an mating face of nut and tighten 8 Ensure plunger sealing...

Страница 20: ...utes 6 Remove the hose and close the valve 7 Properly dispose of used oil and flushing fluid Filter Maintenance We recommend regularly checking cleaning both the inlet final filter and the ballast val...

Страница 21: ...hem Vanes should be replaced in sets and it s always a good idea to have an extra set of vanes on hand for emergencies Be sure O Ring remains in filter cover during reassembly ecking Vane Wear________...

Страница 22: ...t If the pump is frozen move the truck into a heated building Avoid freezing problems You can avoid freezing problems by putting a small amount of diesel fuel into the pump at the end of the day Washi...

Страница 23: ..._______ ________________________________ ________________________________ ________________________________ ________________________________ ________________________________ ___________________________...

Страница 24: ...d operation at excessive vacuum or pressure levels Pump is dirty Ballast filter is clogged or dirty Inlet filter is clogged or dirty Pump uses too much oil ________________________________________ Oil...

Страница 25: ...________________ Locating the source of the trouble If you notice a decrease in pump performance start troubleshooting at the pump Remove the suction and discharge hoses at the pump Start the pump and...

Страница 26: ...the pipe cap 3 Assemble the flange nipple pipe cap and vacuum gage 4 Remove a flange from the four way valve on your pump 5 Start the pump and confirm the location you have chosen to test from is at...

Страница 27: ..._______ ________________________________ ________________________________ ________________________________ ________________________________ ________________________________ ___________________________...

Страница 28: ...04 Hex Bo HHCS 3 8 16 UNC X 1 75 16 305 SOCKE SHCS 5 16 18 UNC X 1 75 2 306 SOCKE SHCS 5_16 18 UNC X 2 25 2 307 HEXAG SS 5_16 18 UNC X 2 00 4 308 NYLOC NYLOCK NUT 5 16 UNC 4 309 SOCKE SHCS 1 4 20 UNC...

Страница 29: ...AUST CHECK WAVE SPRING 31 1 120 041 004 CHECK VALVE 887 32 1 120 067 009 HOUSING 4 WAY VALVE 887 35 1 123 000 003 OIL PUMP 4 PORT BIDIRECTIONAL 36 1 320 LF8 DRIVE TAB 37 1 320 R31 GASKET OIL PUMP 40 1...

Страница 30: ...320 407 028 887 BALLAST VACUUM LINE 131 1 400 026 887 EXTERNAL RETAINING RING 887 133 1 120 220 THERMOMETER 50 400 DEG 2 FACE 2 5 STEM 1 4 18NPT 134 1 320 407 029 887 OIL LINE DRIVE ENDPLATE 135 1 320...

Страница 31: ...EAD CAP SCREW 1 4 20 UNC X 0 625 311 2 LW 1 4 LOCK WASHER 1 4 312 1 HHCS 3 8 16 UNC 0 875 HEX HEAD CAP SCREW 3 8 16 UNC X 0 875 313 9 FW 3 8 FLAT WASHER 3 8 314 4 HSSS 5 16 18 UNC X 1 75 HEXAGON SOCKE...

Страница 32: ...P O Box 685 Traverse City MI 49685 USA 231 941 0215 Phone 231 941 2354 Fax sales natvac com www natvac com 800 253 5500 National Vacuum Equipment Inc...