7.0 Appendix A: Using the AFEval software and the Wavevision 5 Data Capture Board
IMPORTANT NOTE: Before connecting this board to the PC, please install the AFEval Software from the CDROM
included with the development kit or file provided by your National Semiconductor representative. (See Appendix
C)
Connecting the Development Board before installation may result in the board being registered as an unknown
USB device. If this happens you will need to uninstall the device using the Windows Device Manager before
installing the AFEval Software.
7.1 Connecting the WV5 board and LM98640CVAL board for the first time
This development board is designed to connect to a National Semiconductor Wavevision 5 Data Capture Board (WV5)
through the HMZD connector JF2 and connect to a PC over a USB interface running the AFEval Software. The WV5
board comes with its own software GUI. This Wavevision 5 Software is typically used with National Semiconductor’s High
Speed ADC devices and is not required for use with the LM98640CVAL board.
1. With all power off, and the USB cable disconnected, connect the Wavevision 5 board (connector U2) to the
LM98640CVAL board (connector JF2).
2. Configure the JP6 and JP7 jumpers on the LM98640CVAL board for the desired power supply source. For initial
experiments, it is recommended that the jumpers are configured between pins 1 and 2 to allow supply power from
the WV5 board.
3. Plug in the AC-DC power supply to the J2 connector on the Wavevision 5 board. Turn the red rocker switch to
the On position and confirm that the Green LED is illuminated.
4. Connect the USB cable from the PC to the Wavevision 5 board.
5. Allow time for the PC to detect the WV5 board and load the appropriate drivers.
7.2 Proper Board Connection and Power Sequencing
The LM98640QML board should remain connected to the WV5 board unless modifications are required. To connect or
disconnect the LM98640QML board from the system, the following sequences should be observed. Hot swapping of the
LM98640CVAL board to WV5 is not recommended.
Connection Sequence:
1. AFEval software should be closed.
2. All power supplies are off.
3. USB connection to the WV5 board is disabled.
4. Enable the power supply to the WV5 board.
5. Enable the external power supplies to the LM98640CVAL board.
6. Connect the USB cable to the WV5 board.
7. Start the AFEval software.
Disconnection Sequence
1. Close the AFEval software.
2. Disconnect the USB cable from WV5.
3. Disable any external power supplies feeding the LM98640CVAL board.
4. Turn the WV5 power switch to the Off position.