Receive Endpoint FIFO Operation (RXFIFO1, RXFIFO2,
RXFIFO3)
The Receive FIFOs for endpoints 2, 4, and 6 support bulk,
interrupt, and isochronous USB packet transfers larger than
the actual FIFO size. If the packet length exceeds the FIFO
size, software must read the FIFO contents while the USB
packet is being received on the bus. Figure 32 shows the
detailed behavior of receive FIFOs.
Figure 32.
Receive FIFO Operation
RFnS
The Receive FIFO n Size is the total number
of bytes available within the FIFO.
RXRP
The Receive Read Pointer is incremented
with every read by software from the receive
FIFO. This pointer wraps around to zero if
RFnS is reached. RXRP is never incremented
beyond the value of RXWP. If an attempt is
made to read more bytes than are actually
available (FIFO underrun), the last byte is
read repeatedly.
RXWP
The Receive Write Pointer is incremented ev-
ery time the Endpoint Controller writes to the
receive FIFO. This pointer wraps around to
zero if RFnS is reached. An overrun condition
occurs if RXRP equals RXWP and an attempt
is made to write an additional byte.
RXFL
The Receive FIFO Level indicates how many
more bytes can be received until an overrun
condition occurs with the next write to the
FIFO. A FIFO warning is issued if RXFL de-
creases to a specific value. The respective
WARNn bit in the FWR register is set if RXFL
is equal to or less than the number specified
by the RFWL bit in the RXCn register.
RCOUNT
The Receive FIFO Count indicates how many
bytes can be read from the receive FIFO. This
value is accessible by software via the RXSn
register.
18.3
USB CONTROLLER REGISTERS
The CR16 USB node has a set of memory-mapped regis-
ters that can be read/written from the CPU bus to control the
USB interface. Some register bits are reserved; reading
from these bits returns undefined data. Reserved register
bits must always be written with 0.
FLUSH (Resets RXRP and RXWP)
RXRP
RCOUNT = RXWP
-
RXRF
RXWP
RXFL = RXRP
-
RXWP (= RFnS
-
RCOUNT)
RX FIFO n
0X0
RFnS
-
1
+
+
+
DS052
Table 40
USB Controller Registers
Name
Address
Description
MCNTRL
FF FD80h
Main Control Register
NFSR
FF FD8Ah
Node Functional State
Register
MAEV
FF FD8Ch
Main Event Register
ALTEV
FF FD90h
Alternate Event
Register
MAMSK
FF FD8Eh
Main Mask Register
ALTMSK
FF FD92h
Alternate Mask
Register
TXEV
FF FD94h
Transmit Event
Register
TXMSK
FF FD96h
Transmit Mask
Register
RXEV
FF FD98h
Receive Event
Register
RXMSK
FF FD9Ah
Receive Mask
Register
NAKEV
FF FD9Ch
NAK Event Register
NAKMSK
FF FD9Eh
NAK Mask Register
FWEV
FF FDA0h
FIFO Warning Event
Register
FWMSK
FF FDA2h
FIFO Warning Mask
Register
FNH
FF FDA4h
Frame Number High
Byte Register
FNL
FF FDA6h
Frame Number Low
Byte Register
FAR
FF FD88h
Function Address
Register
DMACNTRL
FF FDA8h
DMA Control Register
DMAEV
FF FDAAh
DMA Event Register
DMAMSK
FF FDACh
DMA Mask Register
MIR
FF FDAEh
Mirror Register
DMACNT
FF FDB0h
DMA Count Register
DMAERR
FF FDB2h
DMA Error Register