background image

SPACER

6.

Disclaimers:

6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY WRITTEN DESIGN MATERIALS PROVIDED WITH THE EVM (AND THE

DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL FAULTS." TI DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY
THIRD PARTY PATENTS, COPYRIGHTS, TRADE SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.

6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS AND

CONDITIONS SHALL BE CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY
OTHER INDUSTRIAL OR INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD
PARTY, TO USE THE EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY
INVENTION, DISCOVERY OR IMPROVEMENT MADE, CONCEIVED OR ACQUIRED PRIOR TO OR AFTER DELIVERY OF
THE EVM.

7.

USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS.

USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS

LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS AND CONDITIONS. THIS OBLIGATION
SHALL APPLY WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY
OTHER LEGAL THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.

8.

Limitations on Damages and Liability:

8.1

General Limitations

. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,

INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS ANDCONDITIONS OR THE USE OF THE EVMS PROVIDED HEREUNDER, REGARDLESS OF WHETHER TI HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED
TO, COST OF REMOVAL OR REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES, RETESTING, OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS,
LOSS OF SAVINGS, LOSS OF USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL
BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED.

8.2

Specific Limitations.

IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY WARRANTY OR OTHER OBLIGATION

ARISING OUT OF OR IN CONNECTION WITH THESE TERMS AND CONDITIONS, OR ANY USE OF ANY TI EVM
PROVIDED HEREUNDER, EXCEED THE TOTAL AMOUNT PAID TO TI FOR THE PARTICULAR UNITS SOLD UNDER
THESE TERMS AND CONDITIONS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE CLAIMED. THE EXISTENCE
OF MORE THAN ONE CLAIM AGAINST THE PARTICULAR UNITS SOLD TO USER UNDER THESE TERMS AND
CONDITIONS SHALL NOT ENLARGE OR EXTEND THIS LIMIT.

9.

Return Policy.

Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)

will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.

10.

Governing Law:

These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,

without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2015, Texas Instruments Incorporated

spacer

Содержание ADS54J69

Страница 1: ...n 4 2 2 Hardware Setup Procedure 5 2 3 Software Setup Procedure 6 2 4 Quick Start Trouble Shooting 9 3 Optimizing Evaluation Results 10 3 1 Clocking Optimization 10 3 2 Coherent Input Source 10 3 3 HSDC Pro Settings 10 4 Software Description 11 4 1 ADS54Jxx EVM GUI 11 4 2 Low Level View 12 5 Alternate Hardware Configurations 13 5 1 Clocking Options 13 5 2 Analog Input Options 14 Appendix A Jumper ...

Страница 2: ...mlessly with the TSW14J56EVM Texas Instruments JESD204B data capture pattern generator card through the High Speed Data Converter Pro HSDC Pro software tool for high speed data converter evaluation The ADS54J69EVM was also designed to work with many of the development kits from leading FPGA vendors that contain an FMC connector 1 1 Required Hardware The following equipment is included in the EVM e...

Страница 3: ...onverter Pro software version 4 1 or higher HSDC Pro GUI Updates Rev I for High Speed Data Converter Pro Software version 4 0 or lower 1 3 Evaluation Board Feature Identification Summary The EVM features are labeled in Figure 1 Figure 1 EVM Feature Locations 1 4 References ADS54Jxx EVM software available at www ti com tool ADS54J69EVM ADS54J69 datasheet SBAS713 available at www ti com product ADS5...

Страница 4: ...sed to properly configure the devices on the EVM 1 Download the ADS54Jxx EVM GUI from the TI website The References section of this document contains links to find the software on the TI website 2 Extract the files from the zip file 3 Run setup exe and follow the installation prompts 2 1 2 High Speed Data Converter Pro GUI Installation High Speed Data Converter Pro HSDC Pro is used to control the ...

Страница 5: ... setup using the ADS54J69EVM and TSW14J56EVM is shown in Figure 2 This is the test setup used for the quick start procedure The rest of this section describes the hardware setup steps Figure 2 Quick Start Test Setup 2 2 1 TSW14J56EVM Setup First setup the TSW14J56EVM using the following steps 1 Connect the ADS54J69EVM to the TSW14J56EVM using the FMC connectors 2 Connect one end of the provided 5 ...

Страница 6: ...red once the hardware is properly setup 2 3 1 ADS54J69 GUI Configuration for Decimate by 2 Low Pass Filter Mode 1 Open the ADS54Jxx EVM GUI by going to Start Menu All Programs Texas Instruments ADCs ADS54Jxx EVM GUI 2 Verify that the green USB Status indicator is lit in the top right corner of the GUI If it is not lit click the Reconnect USB button and check the USB Status indicator again If it is...

Страница 7: ...er Pro by going to Start Menu All Programs Texas Instruments High Speed Data Converter Pro The GUI main page looks as shown in Figure 4 Figure 4 HSDC Pro GUI Main Panel 2 When prompted to select the capture board select the TSW14J56 whose serial number corresponds to the serial number on the TSW14J56EVM and click OK This popup can be accessed through the Instrument Options menu 3 If no firmware is...

Страница 8: ... box or press return on the PC keyboard 8 The GUI displays the new lane rate of the SerDes interface based off of the sample rate and other parameters from the loaded configuration files Click OK 9 Click the Instrument Options menu at the top of HSDC Pro and select Reset Board 10 Click Capture in HSDC Pro to capture data from the ADC 11 The results from the captured data of Channel 1 should look l...

Страница 9: ...is not working properly Verify that the USB cable is plugged into the EVM and the PC Check the computer s Device Manager and verify that a USB Serial Device is recognized when the EVM is connected to the PC Verify that the green USB Status LED light in the top right corner of the GUI is lit If it is not lit press Reconnect FTDI button Try restarting the configuration GUI Check default jumper conne...

Страница 10: ... are set precisely to capture an integer number of cycles of the input frequency sometimes called coherent frequency This may yield better SNR results The clock and analog inputs must be frequency locked such as through 10 MHz references in order to achieve coherency 3 3 HSDC Pro Settings HSDC Pro has some settings that can help improve the performance measurements These are highlighted in Table 3...

Страница 11: ...cription ADS54Jxx Enables control of the ADS54Jxx features None of these controls need to be touched for basic operation Instead use the Low Level View tab to load configuration files LMK04828 Enables control of many of the LMK04828 features Configuration files can be used to setup the LMK04828 in known working configurations however this tab can be used to setup more advanced clocking schemes Low...

Страница 12: ...Write Data field This button must be clicked after changing bits in the register data section Write All button Update all registers shown in the Register Map with the values shown in the Register Map log The log can be viewed by double left clicking in the bottom left status bar of this page Read Register button Read from the register highlighted in the Register Map and display the results in the ...

Страница 13: ...o be uninstalled and installed at C64 and C72 The LMK04828 must still be used to provide the device clock to the TSW14J56 and the SYSREF signals to both boards This option provides the best performance as long as the clock source has better phase noise performance than the LMK04828 The source of the EXT ADC clock must be synchronized with the LMK04828 To accomplish this send the 10 MHz reference o...

Страница 14: ...n the onboard VCXO The internal PLLs of the LMK04828 can be used with the onboard VCXO to generate the desired frequencies To use this mode load one of the configuration files named LMK_Config_Onboard_xxxx_MSPS cfg where xxxx corresponds to the desired ADC sampling rate A 10 MHz signal can be brought into the LMK_CLKIN1 input to synchronize to external instruments This is the board default mode of...

Страница 15: ...1 Default is power on Shunt pins 1 2 SJP1 Selects either 3 3 V or GND for Y1 enable Default is open Open SJP3 Selects either diff sync or single ended sync from FMC Default is diff Shunt pins 2 3 A 2 Connector Descriptions The EVM connectors and their function are described in Table 7 Table 7 Connector Descriptions Connector Description J2 Channel A positive analog input J1 Not installed Channel A...

Страница 16: ...used D4 5 VDC power present D2 LMK04828 locked to VCXO D1 VCXO locked to external reference applied to J6 Revision History NOTE Page numbers for previous revisions may differ from page numbers in the current version Changes from A Revision January 2016 to B Revision Page Deleted ADS54J69 GUI Configuration for Decimate by 4 with Digital Mixer section from Software Setup Procedure section 6 Deleted ...

Страница 17: ...ring the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repair such EVM or provide replacements Repaired EVMs shall be warranted for the remainder of the original warranty period Replaced EVMs shall be warranted for a new full ninety 90 day warranty period 3 ...

Страница 18: ... by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Concernant les EVMs avec antennes détachables Conformément à la rég...

Страница 19: ... connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the inputs and outputs kept within the specified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors cu...

Страница 20: ...F REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE LOSS OF DATA OR BUSINESS INTERRUPTION NO CLAIM SUIT OR ACTION SHALL BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED 8 2 Specific Limitations IN NO EVENT SHALL T...

Страница 21: ...esponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failur...

Отзывы: