background image

 

              

11 

          

http://www.national.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BY  USING  THIS  PRODUCT,  YOU  ARE  AGREEING  TO  BE  BOUND  BY  THE  TERMS  AND  CONDITIONS  OF  NATIONAL 
SEMICONDUCTOR'S END USER LICENSE AGREEMENT. DO NOT USE THIS PRODUCT UNTIL YOU HAVE READ AND AGREED 
TO  THE  TERMS  AND  CONDITIONS  OF  THAT  AGREEMENT.  IF  YOU  DO  NOT  AGREE  WITH  THEM,  CONTACT  THE  VENDOR 
WITHIN TEN (10) DAYS OF RECEIPT FOR INSTRUCTIONS ON RETURN OF THE UNUSED PRODUCT FOR A REFUND OF THE 
PURCHASE PRICE PAID, IF ANY. 

 

The  ADC16DV160  Evaluation  Boards  are  intended  for  product  evaluation  purposes  only  and  are  not  intended  for  resale  to  end 
consumers,  is  not  authorized  for  such  use  and  is  not  designed  for  compliance  with  European  EMC  Directive  89/336/EEC,  or  for 
compliance with any other electromagnetic compatibility requirements. 

National Semiconductor Corporation does not assume any responsibility for use of any circuitry or software supplied or described. No 
circuit patent licenses are implied. 

LIFE SUPPORT POLICY 

NATIONAL'S  PRODUCTS  ARE  NOT  AUTHORIZED  FOR  USE  AS  CRITICAL  COMPONENTS  IN  LIFE  SUPPORT  DEVICES  OR 
SYSTEMS  WITHOUT  THE  EXPRESS  WRITTEN  APPROVAL  OF  THE  PRESIDENT  OF  NATIONAL  SEMICONDUCTOR 
CORPORATION. As used herein: 

1.  Life  support  devices  or  systems  are  devices  or  systems 

which,  (a)  are  intended  for  surgical  implant  into  the  body, 
or (b) support or sustain life, and whose failure to perform, 
when properly used in accordance with instructions for use 
provided  in  the  labeling,  can  be  reasonably  expected  to 
result in a significant injury to the user. 

2.  A  critical  component  is  any  component  in  a  life  support 

device  or  system  whose  failure  to  perform  can  be 
reasonably expected to cause the failure of the life support 
device or system, or to affect its safety or effectiveness. 

 

National Semiconductor Corporation

 

Americas

 

Tel:      1-800-272-9959 
Fax:     1-800-737-7018 
Email: [email protected] 

National Semiconductor Europe

 

Fax: +49 (0) 1 80-530 85 86 
Email: [email protected] 
Deutsch Tel: +49 (0) 699508 6208 
English   Tel: +49 (0) 870 24 0 2171 
Français Tel: +49 (0) 141 91 8790 

National Semiconductor 
Asia Pacific Customer 
Response Group

 

Tel:  65-2544466 
Fax: 65-2504466 
Email:[email protected] 

National Semiconductor 
Japan Ltd.

 

Tel:   81-3-5639-7560 
Fax:  81-3-5639-7507 

www.national.com 

 

 

 

 

National does not assume any responsibility for any circuitry described, no circuit patent licenses are implied and National reserves the right at any time 
without notice to change said circuitry and specifications. 

 

Содержание ADC16DV160HFEB

Страница 1: ...1 http www national com National Semiconductor June 16 2010 Rev 1 0 ADC16DV160HFEB Evaluation Board User s Guide ADC16DV160 Dual 16 Bit 160 MSPS A D Converter 2009 National Semiconductor Corporation ...

Страница 2: ...ick Start 4 4 0 Functional Description 4 4 1 Analog Input 4 4 2 ADC reference circuitry 4 4 3 ADC clock circuit 5 4 4 Power Supply Connections 5 5 0 Installing the ADC16DV160 Evaluation Board 5 6 0 Hardware Schematic 6 7 0 Evaluation Board Layout 7 8 0 Evaluation Board Bill of Materials 10 ...

Страница 3: ...e captured data upon command and in addition to a frequency domain plot shows dynamic performance in the form of SNR SINAD THD SFDR and ENOB The latest WaveVision software is available through the National Semiconductor website http www national com analog adc wavevision5 2 0 Board Assembly The ADC16DV160 Evaluation Board comes pre assembled Refer to the Bill of Materials in Section 8 for a descri...

Страница 4: ...nnect a 160 MHz signal from a 50 Ohm source to connector J4 for the input Clock Be sure to use a bandpass filter before the Evaluation Board Set the amplitude to 18 dBm 4 Connect a signal from a 50 Ohm source to connector J2 I Channel or J3 Q Channel Be sure to use a bandpass filter before the Evaluation Board For best results also attach a 3dB 50 ohm attenuator right at the input SMA of the eval ...

Страница 5: ...applied before power to the ADC16DV160 Evaluation Board to insure that the FPGA on the WaveVision5 Data Capture Board is not damaged A low noise sinusoidal signal source should be connected to the Clock Input SMA connector J4 An appropriate signal source should be connected to the Signal Input SMA connector J2 When evaluating dynamic performance an appropriate signal generator such as R S SMA 100A...

Страница 6: ... B5 B5 B6 B6 B7 B7 B8 B8 B9 B9 B10 B10 B11 B11 B12 B12 B13 B13 B14 B14 B15 B15 B16 B16 B17 B17 B18 B18 B19 B19 B20 B20 B21 B21 B22 B22 B23 B23 B24 B24 C1 C1 C2 C2 C3 C3 C4 C4 C5 C5 C6 C6 C7 C7 C8 C8 C9 C9 C10 C10 C11 C11 C12 C12 C13 C13 C14 C14 C15 C15 C16 C16 C17 C17 C18 C18 C19 C19 C20 C20 C21 C21 C22 C22 C23 C23 C24 C24 D1 D1 D2 D2 D3 D3 D4 D4 D5 D5 D6 D6 D7 D7 D8 D8 D9 D9 D10 D10 D11 D11 D12 D...

Страница 7: ...7 http www national com 7 0 Evaluation Board Layout Layer 1 Component Side Layer 2 Ground ...

Страница 8: ...8 http www national com Layer 3 Power Layer 4 Ground Clock ...

Страница 9: ...9 http www national com Layer 5 Ground Layer 6 Circuit Side ...

Страница 10: ...D_TP1 GND_TP2 GND_TP3 TestPoint Keystone 5002 GND_TP4 GND2_TP1 GND2_TP2 17 1 NSC J1 Connector Future Bus Header96 Tyco Electronics 5223514 3 18 1 J2 INPUT_I Johnson 142 0701 851 19 1 J3 INPUT_Q Johnson 142 0701 851 20 1 J4 CLK_DIFF Johnson 142 0701 851 22 1 P1 VA3 0 Phoenix Contacts 1759017 23 1 P2 VA1 8 Phoenix Contacts 1759017 24 1 P3 VDR Phoenix Contacts 1759017 25 1 P4 VAD3 0 Phoenix Contacts ...

Страница 11: ... NATIONAL SEMICONDUCTOR CORPORATION As used herein 1 Life support devices or systems are devices or systems which a are intended for surgical implant into the body or b support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user 2 A critical componen...

Страница 12: ...for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications and acknowledge and agre...

Страница 13: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments ADC16DV160HFEB NOPB ...