5
Technical Data
Charging Modes
Bulk Charging Time
12V
6V
SYMBOL
DESCRIPTION
This mode is
normally used for
WET, MF, VRLA,
AGM, GEL &
Calcium batteries
This mode is
normally used for
WET, MF, VRLA,
AGM, GEL &
Calcium batteries
Input Voltage AC
220V-240Vac - 50/60Hz
Input Current
0.18A
RMS
Max
Charge Current
1A max
Output Power
14.4W
Stand-By Power
< 1W
Maximum Efficiency
> 70%
Battery Types
6V &12V Lead acid (Flooded WET, MF, VRLA, AGM, GEL & Calcium)
Battery Capacity
6Volt Mode: 1.2Ah - 20Ah
12Volt Mode: 1.2Ah - 20Ah
Minimum Battery Voltage >2.5V for 6V battery mode >7.5V for 12V battery mode
Back Current Drain
<10 mA
Storage Temperature
-25°C to 70°C
Operation Temperature 0°C to +40°C
Safety Class
Class II
Type of Charger
5-step, fully automatic charger
Housing Protection
IP60 (dust proof) for indoor use only
Noise Level
< 50dB (Tested from a distance of 50cm)
Weight
0.35 kg
Dimensions (L x W x H)
109.4 x 65.0 x 38.5mm
Mode 6V/1A
Mode 12V/1A
Specifications
The NL1 Battery Charger has extremely low back current drain.
Battery
Size (Ah)
For
±
80%
Charge (hours)
1.2
2
6
7
8
9
12
14
20
23
(Back current drain is the amount of current drawn by the charger from the battery,
when the charger is connected to the battery without the
AC