Appendix A
Specifications
VXIpc-850 Series User Manual
A- 2
© National Instruments Corporation
Environmental
Characteristic
Specification
Temperature
0
°
to 55
°
C Operating;
-20
°
to 70
°
C Storage
Relative Humidity
0% to 95% Noncondensing, Operating;
0% to 95% Noncondensing, Storage
EMI
FCC Class A Verified , EC Verified
Vibration
Operational: 5 to 500 Hz, 0.31g, 3 axes
Non-operations: 5 to 500 Hz, 2.5g, 3 axes
Functional Shock
MIL-T-28800E Class 3 (per Section 4.5.5.4.1)
Half-Sine Shock Pulse (11 ms duration, 30g peak, 3
shocks per face)
Note:
Random vibration profiles were developed in accordance with
MIL -T-28800E and MIL-STD-810E Method 514. Test levels exceed those
recommended in MIL-STD-810E for Category 1 (Basic Transportation,
Figures 514.4-1 through 514.4-3). Test report available upon request.
Requirements
Characteristic
Specification
VXIbus Configuration Space
64 B
A24 or A32 Space
16 KB Minimum (Programmable)
Performance
VME Transfer Rate
Peak
D32
33 MB/s
Sustained
D32
Reads
13.76 MB/s
Writes
11.37 MB/s