background image

NI USB-9265 User Guide and Specifications

2

ni.com

Dimensions

Figure 2 shows the NI USB-9265 device dimensions.

Figure 2.  

NI USB-9265 Device Dimensions in Millimeters (Inches)

Safety Guidelines

Operate the NI USB-9265 only as described in this user guide.

Hot Surface

This icon denotes that the component may be hot. Touching this component 

may result in bodily injury.

Safety Guidelines for Hazardous Voltages

A hazardous voltage is a voltage greater than 42.4 V

pk

 or 60 VDC to earth 

ground. If hazardous voltages are connected to the module, take the 
following precautions. 

Caution

Ensure that hazardous voltage wiring is performed only by qualified personnel 

adhering to local electrical standards.

Caution

Do 

not

 mix hazardous voltage circuits and human-accessible circuits on the same 

module.

Caution

Make sure that devices and circuits connected to the module are properly 

insulated from human contact.

Hi-Speed USB Carrier 

NI USB-9162 

120.68 mm

(4.751 in.)

118.26 mm

(4.656 in.)

88.12 mm
(3.469 in.)

25.34 mm
(0.998 in.)

Содержание USB-9265

Страница 1: ...Instruments USB 9265 and lists the device specifications Introduction The NI USB 9265 consists of two components an NI 9265 module and an NI USB 9162 carrier as shown in Figure 1 Figure 1 NI USB 9265...

Страница 2: ...es A hazardous voltage is a voltage greater than 42 4 Vpk or 60 VDC to earth ground If hazardous voltages are connected to the module take the following precautions Caution Ensure that hazardous volta...

Страница 3: ...erminals are not accessible Figure 3 NI 9932 Connector Backshell Related Documentation Each application software package and driver includes information about writing applications for taking measureme...

Страница 4: ...eneral information about measurement concepts key NI DAQmx concepts and common applications that are applicable to all programming environments Start All Programs National Instruments NI DAQ NI DAQmx...

Страница 5: ...ontains NI DAQmxmeasurementconcepts and step by step instructions about creating a measurement task using the DAQ Assistant Help Contents then select Using LabWindows CVI Data Acquisition Taking an NI...

Страница 6: ...l Basic NET Start All Programs National Instruments NI DAQ NI DAQmx NET Reference Help Expand NI Measurement Studio Help NI Measurement Studio NET Class Library Reference to view the function referenc...

Страница 7: ...uctions that accompany your software Example Programs The NI DAQmx media contains example programs that you can use to get started programming with the NI USB 9265 Refer to the NI DAQmx for USB Device...

Страница 8: ...5 into the NI USB 9162 Carrier The NI 9265 C Series module and NI USB 9162 carrier are packaged separately Refer to Figure 5 while completing the following assembly steps 1 Make sure that no signals a...

Страница 9: ...s a green LED next to the USB connector The LED indicator indicates device status as listed in Table 2 When the device is connected to a USB port the LED blinks steadily to indicate that the device is...

Страница 10: ...hat is internally connected to the isolated ground reference of the module The USB 9265 also has a terminal for an external power supply Vsup and an external power supply common terminal Power Supply...

Страница 11: ...NI USB 9265 You must connect an external power supply to the NI USB 9265 This power supply provides the current for the devices you connect to the module Connect the positive lead of the power supply...

Страница 12: ...ferrules Refer to Figure 3 for an illustration of the NI 9932 connector backshell Figure 9 10 Terminal Detachable Screw Terminal Connector with Ferrule Specifications The following specifications are...

Страница 13: ...ion AO Vsup Overvoltage 40 V Short circuit Indefinitely Noise 600 nArms Crosstalk 90 dB Settling time to 1 LSB Full scale step 10 s 1 mA step 5 s Glitch energy Unmeasurable Monotonicity 16 bits DNL 1...

Страница 14: ...pe it with a dry towel Maximum Voltage1 Connect only voltages that are within the following limits Channel to COM or Vsup to COM 40 V max Isolation Voltages Channel to channel No isolation between cha...

Страница 15: ...1010 1 EN 61010 1 UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refer to the product label or visit ni com certification search by module number or product line and click the appr...

Страница 16: ...ive safety 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To o...

Страница 17: ...lso has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions...

Страница 18: ...respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National I...