UMI Accessory User Guide — UMI-Flex4 Specifications
34
www.natinst.com
UMI-Flex4 Specifications
The following specifications apply only to the UMI-Flex4 accessory. To
obtain a system specification, you must account for your motion controller.
Please refer to your controller specifications to determine overall system
specifications.
These specifications are typical at 25 °C unless otherwise specified. Refer
to your motion controller user manual for detailed specifications on
encoder inputs, limit and home switch inputs, high speed inputs, breakpoint
outputs, and analog inputs.
Axis Inhibit Out
Voltage range..........................................0 to 5 VDC
Output current.........................................16 mA sink max.
Operating Environment
Temperature............................................0 to 55 °C
Storage temperature ................................–20 to 70 °C
Relative humidity ...................................10 to 90% (noncondensing)
Power Requirements
+5 VDC...................................................0.2 A + user-defined encoder
power
+ISO
Voltage....................................................5 to 24 VDC
Current ....................................................User-defined isolated signals
Host Bus Voltage Interlock
Voltage....................................................5 VDC ± 5%
Physical
Dimensions .............................................23.62 by 10.03 cm
(9.3 by 3.95 in.)
Universal DIN-rail base
(supplied)