SCXI controller (NI 4021 or NI 4060)

1/8 in. Phillips screwdriver

Unpacking

The SCXI-1362 is shipped in an antistatic package to prevent electrostatic
damage to the device. Electrostatic discharge can damage several
components on the device.

Caution

Never

touch the exposed pins of connectors.

To avoid such damage in handling the device, take the following
precautions:

Ground yourself using a grounding strap or by holding a grounded
object.

Touch the antistatic package to a metal part of your computer chassis
before removing the device from the package.

Remove the device from the package and inspect the device for loose
components or any sign of damage. Notify National Instruments if the
device appears damaged in any way. Do

not

install a damaged device

into your computer.

Store the SCXI-1362 in the antistatic envelope when not in use.

Safety Information

Cautions

To meet EMC/EMI cooling and safety compliance requirements, the SCXI-1362

device must be installed in a chassis with the covers and chassis filler panels properly
installed.

Do

not

operate the device in an explosive atmosphere or where there may be flammable

gases or fumes.

Do

not

operate damaged equipment. The safety protection features built into this device

can become impaired if the device becomes damaged in any way. If the device is damaged,
turn the device off and do

not

use it until service-trained personnel can check its safety.

If necessary, return the device to National Instruments for service and repair to ensure that
its safety is not compromised.

Do

not

operate this equipment in a manner that contradicts the information specified in this

document. Misuse of this equipment could result in a shock hazard.

Содержание SCXI-1362

Страница 1: ...onal Instruments SCXI 1362 Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com modular systems national instruments scxi SCXI 1...

Страница 2: ...e SCXI 1362 kit Use the SH9MD AUX cable to connect the digital communication signals from the NI 4021 or NI 4060 to the AUX IN connector of the SCXI 1362 In SCXI multichassis configurations use a SH9M...

Страница 3: ...way Do not install a damaged device into your computer Store the SCXI 1362 in the antistatic envelope when not in use Safety Information Cautions To meet EMC EMI cooling and safety compliance require...

Страница 4: ...ith a soft non metallic brush Remove other contaminants with a stiff non metallic brush The unit must be completely dry and free from contaminants before returning it to service The adapter must be us...

Страница 5: ...i com Figure 1 Installing the SCXI 1362 Kit 1 SCXI Chassis 2 SCXI 1362 Adapter 3 Small Screw 4 AUX IN Connector 5 AUX OUT Connector 6 SH9MD AUX Cable FUSE PULL 1 6 2 3 3 LV ANALOG FROM DMM OR PREVIO U...

Страница 6: ...Kit section 2 Connect the other end of the SH9MD AUX cable to the AUX OUT connector of the previously installed SCXI 1362 adapter 3 Repeat steps 1 and 2 for any additional SCXI 1362 adapter kits Figu...

Страница 7: ...ty Evaluated to EN 61326 1 1997 A1 1998 Table 1 Note For full EMC and EMI compliance you must operate this device with shielded cabling See the Declaration of Conformity DoC for this product for any a...

Отзывы: