manualshive.com logo in svg
background image

SCXI-1356 Shielded Cable Installation Guide

10

ni.com

Note

Avoid using the MIO-16 Branch digital lines by themselves when using the 

SCXI-1356.

You can access the PFI lines on the MIO-16 Branch of the cable for 
triggering through the SCXI-1349 side connector using the SCXI-1180 
Feedthrough Panel. For more information on the SCXI-1180, refer to the 

SCXI-1180/1181 User Manual.

ACH16-ACH63 Branch Connections

You can connect the ACH16–ACH63 branch of the cable, using the 
AI-48/DIO-24, to the SCXI-1180 feedthrough panel or the SCXI-1181 
breadboard module. Table 2 lists the pin designations for connections 
between the VXI-MIO Series module and the ACH16–ACH63 cable.

GPCTR1_OUT

B30

40

43

PFI5/UPDATE*

C30

6

44

PFI6/WFTRIG

A31

5

45

PFI7/STARTSCAN

B31

38

46

PFI8/GPCTR0_SOURCE

C31

37

47

PF19/GPCTR0_GATE

A32

3

48

GPCTR0_OUT

B32

2

49

FREQ_OUT

C32

1

50

1

 SENSE for ACH0–ACH15

2

 This pin is not connected on the VXI-MIO-64XE-10

Table 2.  

Cable Connections for the ACH16

ACH63 Branch

Signal Names

Connector Pin Numbers

96-Pin

68-Pin

50-Pin

ACH16

A17

68

1

ACH24

C16

34

2

ACH17

B16

33

3

ACH25

A16

67

4

ACH18

C15

32

5

Table 1.  

Cable Connections for the MIO-16 Branch (Continued)

Signal Names

Connector Pin Numbers

96-Pin

68-Pin

50-Pin

Содержание SCXI-1356

Страница 1: ...00 pin male connector at one end and two 68 pin female connectors on the branched end One 68 pin connector branch is labeled MIO 16 and the other is labeled ACH16 ACH63 Refer to Figure 1 for the parts...

Страница 2: ...n introduction to a key concept This font also denotes text that is a placeholder for a word or value that you must supply monospace Text in this font denotes text or characters that you should enter...

Страница 3: ...a temporary conductivity caused by condensation must be expected Pollution degree 3 means that conductive pollution occurs or dry nonconductive pollution occurs that becomes conductive due to condensa...

Страница 4: ...circuits and circuit breakers Other examples of installation category III are wiring including cables bus bars junction boxes switches socket outlets in the building fixed installation and equipment f...

Страница 5: ...CXI chassis 5 Connect the MIO 16 branch of the cable to the 68 pin connector of the SCXI 1349 6 Plug the socket connector of the AI 48 DIO 24 into the rear signal connector of the SCXI module or the f...

Страница 6: ...SCXI Modules 2 SCXI Chassis 3 SCXI 1349 Adapter 4 MIO 16 Branch of SCXI 1356 Shielded Cable 5 VXI MIO Series Module 6 96 Pin Male Connector End of SCXI 1356 Shielded Cable 7 ACH16 ACH63 Branch of SCX...

Страница 7: ...MIO Series module you use determines which SCXI modules you can use with the SCXI 1356 Connecting the SCXI 1356 to a VXI MIO Series Module The MIO 16 branch of the cable brings the MIO 16 portion of t...

Страница 8: ...63 or SCXI 1163HV SCXI 1180 or SCXI 1181 Table 1 lists the pin assignments for connections between the VXI MIO Series module and the MIO 16 branch of the cable Table 1 Cable Connections for the MIO 16...

Страница 9: ...O1 B25 17 27 DIO5 C25 51 28 DIO2 A26 49 29 DIO6 B26 16 30 DIO3 C26 47 31 DIO7 A27 48 32 5V A28 8 14 34 35 SCANCLK C27 46 36 DIO4 A25 19 26 DIO1 B25 17 27 DIO5 C25 51 28 DIO2 A26 49 29 DIO6 B26 16 30 D...

Страница 10: ...h panel or the SCXI 1181 breadboard module Table 2 lists the pin designations for connections between the VXI MIO Series module and the ACH16 ACH63 cable GPCTR1_OUT B30 40 43 PFI5 UPDATE C30 6 44 PFI6...

Страница 11: ...B12 27 15 ACH31 A12 61 16 ACH32 C11 26 17 ACH40 B11 60 18 ACH33 A11 59 19 ACH41 C10 25 20 ACH34 B10 24 21 ACH42 A10 58 22 ACH35 C9 23 23 ACH43 B9 57 24 AISENSE2 A9 56 25 AIGND B17 22 26 ACH36 C8 55 2...

Страница 12: ...mode voltage Channel to earth 250 V installation category II Channel to channel 250 V installation category II ACH48 A6 17 35 ACH56 C5 51 36 ACH49 B5 16 37 ACH57 A5 50 38 ACH50 C4 49 39 ACH58 B4 15 40...