SCXI-1356 Shielded Cable Installation Guide

safety protection built into the product if the product is damaged in any 
way. If the product is damaged, return it to National Instruments for repair.

Do 

not

 substitute parts or modify the product except as described in this 

document. Use the product only with the chassis, modules, accessories, and 
cables specified in the installation instructions. You 

must

 have all covers 

and filler panels installed during operation of the product.

Do 

not

 operate the product in an explosive atmosphere or where there may 

be flammable gases or fumes. Operate the product only at or below the 
pollution degree stated in th

Specifications

 

section. Pollution is foreign 

matter in a solid, liquid, or gaseous state that can reduce dielectric strength 
or surface resistivity. The following is a description of pollution degrees:

Pollution degree 1 means no pollution or only dry, nonconductive 
pollution occurs. The pollution has no influence.

Pollution degree 2 means that only nonconductive pollution occurs in 
most cases. Occasionally, however, a temporary conductivity caused 
by condensation must be expected.

Pollution degree 3 means that conductive pollution occurs, or dry, 
nonconductive pollution occurs that becomes conductive due to 
condensation.

Clean the product with a soft nonmetallic brush. Make sure that the product 
is completely dry and free from contaminants before returning it to service.

You 

must 

insulate signal connections for the maximum voltage for which 

the product is rated. Do 

not

 exceed the maximum ratings for the product. 

Remove power from signal lines before connecting them to or 
disconnecting them from the product.

Operate this product only at or below the installation category stated in the 

Specifications

 section.

The following is a description of installation categories:

Installation category I is for measurements performed on circuits not 
directly connected to MAINS

1

. This category is a signal level such as 

voltages on a printed wire board (PWB) on the secondary of an 
isolation transformer. 

Examples of installation category I are measurements on circuits not 
derived from MAINS and specially protected (internal) 
MAINS-derived circuits.

1   

MAINS is defined as the electricity supply system to which the equipment concerned is designed to be connected either for 
powering the equipment or for measurement purposes.

Содержание SCXI-1356

Страница 1: ...00 pin male connector at one end and two 68 pin female connectors on the branched end One 68 pin connector branch is labeled MIO 16 and the other is labeled ACH16 ACH63 Refer to Figure 1 for the parts...

Страница 2: ...n introduction to a key concept This font also denotes text that is a placeholder for a word or value that you must supply monospace Text in this font denotes text or characters that you should enter...

Страница 3: ...a temporary conductivity caused by condensation must be expected Pollution degree 3 means that conductive pollution occurs or dry nonconductive pollution occurs that becomes conductive due to condensa...

Страница 4: ...circuits and circuit breakers Other examples of installation category III are wiring including cables bus bars junction boxes switches socket outlets in the building fixed installation and equipment f...

Страница 5: ...CXI chassis 5 Connect the MIO 16 branch of the cable to the 68 pin connector of the SCXI 1349 6 Plug the socket connector of the AI 48 DIO 24 into the rear signal connector of the SCXI module or the f...

Страница 6: ...SCXI Modules 2 SCXI Chassis 3 SCXI 1349 Adapter 4 MIO 16 Branch of SCXI 1356 Shielded Cable 5 VXI MIO Series Module 6 96 Pin Male Connector End of SCXI 1356 Shielded Cable 7 ACH16 ACH63 Branch of SCX...

Страница 7: ...MIO Series module you use determines which SCXI modules you can use with the SCXI 1356 Connecting the SCXI 1356 to a VXI MIO Series Module The MIO 16 branch of the cable brings the MIO 16 portion of t...

Страница 8: ...63 or SCXI 1163HV SCXI 1180 or SCXI 1181 Table 1 lists the pin assignments for connections between the VXI MIO Series module and the MIO 16 branch of the cable Table 1 Cable Connections for the MIO 16...

Страница 9: ...O1 B25 17 27 DIO5 C25 51 28 DIO2 A26 49 29 DIO6 B26 16 30 DIO3 C26 47 31 DIO7 A27 48 32 5V A28 8 14 34 35 SCANCLK C27 46 36 DIO4 A25 19 26 DIO1 B25 17 27 DIO5 C25 51 28 DIO2 A26 49 29 DIO6 B26 16 30 D...

Страница 10: ...h panel or the SCXI 1181 breadboard module Table 2 lists the pin designations for connections between the VXI MIO Series module and the ACH16 ACH63 cable GPCTR1_OUT B30 40 43 PFI5 UPDATE C30 6 44 PFI6...

Страница 11: ...B12 27 15 ACH31 A12 61 16 ACH32 C11 26 17 ACH40 B11 60 18 ACH33 A11 59 19 ACH41 C10 25 20 ACH34 B10 24 21 ACH42 A10 58 22 ACH35 C9 23 23 ACH43 B9 57 24 AISENSE2 A9 56 25 AIGND B17 22 26 ACH36 C8 55 2...

Страница 12: ...mode voltage Channel to earth 250 V installation category II Channel to channel 250 V installation category II ACH48 A6 17 35 ACH56 C5 51 36 ACH49 B5 16 37 ACH57 A5 50 38 ACH50 C4 49 39 ACH58 B4 15 40...

Страница 13: ...sources include frequently asked questions knowledge bases product specific troubleshooting wizards manuals drivers software updates and more Web support is available through the Technical Support sec...

Страница 14: ...ermany 089 741 31 30 Greece 30 1 42 96 427 Hong Kong 2645 3186 India 91 80 535 5406 Israel 03 6393737 Italy 02 413091 Japan 03 5472 2970 Korea 02 3451 3400 Malaysia 603 9596711 Mexico 001 800 010 0793...

Отзывы: