National Instruments SCC-FT01 Скачать руководство пользователя страница 9

©

 National Instruments Corporation

9

SCC-FT01 Feedthrough Module User Guide

PFI 7/AI SAMP CLK, AI + Cascaded, AI + Cascaded REF,
AI – Cascaded, AI – Cascaded REF, and AI SENSE Cascaded signals are 
available for the second-stage AI SCC sockets only. The P0.(

X

) signal is 

available for the first-stage AI SCC sockets only. Refer to Table 2 for pad 
definitions.

When the E Series DAQ device is configured in NRSE AI mode, design 
your prototype circuitry so that the output of the SCC-FT01 to the E Series 
DAQ device is referenced single-ended to AI GND on the SC-2345.

Note

On the SC-2345, the AI GND and AI SENSE signals join at connector J24.

Analog Output

To use the SCC-FT01 for AO signal conditioning, use the pads above 
connector J2 labeled 

AO

 for connections to the breadboard area. The 

AO

column in Table lists the signals available to each pad. Plug the 

SCC-FT01 into any AO socket on the SC-2345. 

The AO 0 and AO 1 signals depend on which AO SCC socket you use. 
If you plug the SCC-FT01 into the AO SCC socket J17, the DAC (A) pad 
connects to AO 0 and the DAC (B) pad to AO 1 on the E Series DAQ 
device. These pad connections are reversed when the SCC-FT01 is plugged 
into AO SCC socket J18, and the DAC (A) pad connects to AO 1 and 
DAC (B) pad to AO 0 on the E Series DAQ device.

Counter

To use the SCC-FT01 for CTR functions, use the pads above connector J2 
labeled 

CTR

 for connections to the breadboard area. The 

CTR CH0

 and 

CTR CH1

 columns in Table 2 list the signals available to each pad. The 

signals available depend on which SCC socket you use.

If you plug the SCC-FT01 into the CTR CH0 socket J19, the pads under 
CTR CH0 on the board connect to signals associated with CTR channel 0 
and AO of the E Series DAQ device. When the SCC-FT01 is plugged into 
the CTR CH1 socket J20, the pads under CTR CH1 on the board connect 
to signals associated with CTR channel 1 and AI of the E Series DAQ 
device.

Содержание SCC-FT01

Страница 1: ...l action The sequence File Page Setup Options directs you to pull down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to...

Страница 2: ...ions SC 2345 SC 2345 refers to both the SC 2345 connector block and the SC 2345 with configurable connectors SCC SCC refers to any SCC series signal conditioning module What You Need to Get Started To...

Страница 3: ...gnal wires Caution If you plug the unmodified SCC FT01 into any SCC socket other than single stage AI sockets J1 through J8 or AO sockets J17 and J18 you can damage the E Series DAQ device You can plu...

Страница 4: ...nformation on AI modes refer to the SC 2345 User Manual For information on AI configuration modes refer to the DAQ device documentation When you plug the SCC FT01 into an AO SCC socket the following c...

Страница 5: ...NRSE mode Refer to the Measurement Automation Explorer Help for more information and instructions on configuring channels For more information about configuring the SCC FT01 using NI DAQmx refer to t...

Страница 6: ...5 Figure 1 SCC FT01 Parts Locator Diagram Table 2 shows the signals available for circuit design when you plug the SCC FT01 into each type of SCC socket on the SC 2345 The pad numbers correspond to th...

Страница 7: ...GND 5 V AO GND B N A or AI Cascaded REF1 PFI 1 AI REF TRIG or AI Cascaded REF1 4 PFI 7 AI SAMPLE C LK or P0 X 2 15 V AO GND A FREQ OUT FREQ OUT 5 AI GND 15 V and REF 5 V J17 AO 0 J18 AO 1 PFI 5 AO SA...

Страница 8: ...ration Figure 2c illustrates single stage AI configuration Analog Input and Digital Input Output To use the SCC FT01 for AI or digital signal conditioning use the pads above connector J2 labeled AI P0...

Страница 9: ...he SCC FT01 into any AO socket on the SC 2345 The AO 0 and AO 1 signals depend on which AO SCC socket you use If you plug the SCC FT01 into the AO SCC socket J17 the DAC A pad connects to AO 0 and the...

Страница 10: ...ick Start Guide Specifications These ratings are typical at 25 C unless otherwise stated Analog Number of input channels 1 DIFF or 2 SE when plugged into an AI socket on the SC 2345 Number of output c...

Страница 11: ...rtification column Electromagnetic Compatibility Emissions EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity EN 61326 1997 A2 2001 Table 1 CE C Tick and FCC Part 15 Class A Compliant Note For...

Отзывы: