National Instruments SCC-FT01 Скачать руководство пользователя страница 5

©

 National Instruments Corporation

5

SCC-FT01 Feedthrough Module User Guide

When you configure the SC-2345 as an accessory to the E Series DAQ 
device in Measurement & Automation Explorer (MAX), the program 
automatically configures the SC-2345 in nonreferenced single-ended 
(NRSE) mode. Connect the signal source to single-ended channels on the 
SCC-FT01 while the SC-2345 is configured in the NRSE AI configuration.

You can configure the E Series DAQ device to read signals from the 
SCC-FT01 in differential mode. Use a virtual channel in MAX or 
application software to configure the E Series DAQ device to read the 
signal in differential mode. When you read a signal in differential mode, 
you use two channels for one measurement, but you avoid ground loops and 
get a better signal by rejecting common-mode signal noise.

You can configure the E Series DAQ device on a per channel basis with 
application software or virtual channels. For example, you can have 
channels 0 and 8 in differential mode and 1 to 7 and 9 to 15 in NRSE mode. 
Refer to the 

Measurement & Automation Explorer Help

 for more 

information and instructions on configuring channels.

For more information about configuring the SCC-FT01 using NI-DAQmx, 
refer to the 

SCC Quick Start Guide

.

Customizing the SCC-FT01

You can customize the SCC-FT01 to connect to any of the AI, AO, digital 
input/output, or counter signals of the E Series DAQ device. After you 
customize the SCC-FT01, you can plug it into any SCC socket on 
the SC-2345 except the SCC power socket. The SCC-FT01 PCB 
contains 2.54 sq cm (1 sq in.) of prototyping breadboard area. This area 
accommodates as many as four 8-pin integrated circuits and other discrete 
components such as resistors and capacitors.

Place the SCC-FT01 prototyping module label, which is included in the kit, 
over the SCC-FT01 feedthrough module label on the SCC enclosure. This 
label does not contain signal names, so you can customize the assignment 
of the screw terminals.

Circuit Design

You must disassemble the SCC-FT01 to install custom circuitry. 
Complete the following steps to open the module.

1.

Remove the screw from the back (wide unlabeled side).

2.

Turn the front (wide labeled side) toward you.

3.

Place the screw terminal receptacle on the left.

Содержание SCC-FT01

Страница 1: ...l action The sequence File Page Setup Options directs you to pull down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to...

Страница 2: ...ions SC 2345 SC 2345 refers to both the SC 2345 connector block and the SC 2345 with configurable connectors SCC SCC refers to any SCC series signal conditioning module What You Need to Get Started To...

Страница 3: ...gnal wires Caution If you plug the unmodified SCC FT01 into any SCC socket other than single stage AI sockets J1 through J8 or AO sockets J17 and J18 you can damage the E Series DAQ device You can plu...

Страница 4: ...nformation on AI modes refer to the SC 2345 User Manual For information on AI configuration modes refer to the DAQ device documentation When you plug the SCC FT01 into an AO SCC socket the following c...

Страница 5: ...NRSE mode Refer to the Measurement Automation Explorer Help for more information and instructions on configuring channels For more information about configuring the SCC FT01 using NI DAQmx refer to t...

Страница 6: ...5 Figure 1 SCC FT01 Parts Locator Diagram Table 2 shows the signals available for circuit design when you plug the SCC FT01 into each type of SCC socket on the SC 2345 The pad numbers correspond to th...

Страница 7: ...GND 5 V AO GND B N A or AI Cascaded REF1 PFI 1 AI REF TRIG or AI Cascaded REF1 4 PFI 7 AI SAMPLE C LK or P0 X 2 15 V AO GND A FREQ OUT FREQ OUT 5 AI GND 15 V and REF 5 V J17 AO 0 J18 AO 1 PFI 5 AO SA...

Страница 8: ...ration Figure 2c illustrates single stage AI configuration Analog Input and Digital Input Output To use the SCC FT01 for AI or digital signal conditioning use the pads above connector J2 labeled AI P0...

Страница 9: ...he SCC FT01 into any AO socket on the SC 2345 The AO 0 and AO 1 signals depend on which AO SCC socket you use If you plug the SCC FT01 into the AO SCC socket J17 the DAC A pad connects to AO 0 and the...

Страница 10: ...ick Start Guide Specifications These ratings are typical at 25 C unless otherwise stated Analog Number of input channels 1 DIFF or 2 SE when plugged into an AI socket on the SC 2345 Number of output c...

Страница 11: ...rtification column Electromagnetic Compatibility Emissions EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity EN 61326 1997 A2 2001 Table 1 CE C Tick and FCC Part 15 Class A Compliant Note For...

Отзывы: