National Instruments sbRIO-9205 Скачать руководство пользователя страница 22

all channels and also provides improved noise rejection compared
to an RSE connection.

Connecting Wires to a Spring-Terminal
Connector

Complete the following steps to connect wires to the spring-
terminal connector using the flathead screwdriver that is included
with your C Series module or a flathead screwdriver with a blade
smaller than 2.3 mm x 1.0 mm (0.09 in. x 0.04 in.).

NI 9205 Getting Started Guide

  | 

© National Instruments

  | 

21

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание sbRIO-9205

Страница 1: ...rutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In sto...

Страница 2: ...GETTING STARTED GUIDE NI 9205 16 AI Differential 32 AI Single Ended 200 mV to 10 V 16 Bit 250 kS s Aggregate hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Страница 3: ...h component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9205 only as described in this document Caution Do not operate the NI 9205 in a...

Страница 4: ...h Spring Terminal Isolation Voltages Channel to channel None Channel to earth ground2 Continuous 250 Vrms Measurement Category II Withstand 2 300 Vrms verified by a 5 s dielectric withstand test 1 The...

Страница 5: ...on Do not connect the NI 9205 to signals or use for measurements within Measurement Categories III or IV NI 9205 with DSUB Isolation Voltages Channel to channel None Channel to earth ground Continuous...

Страница 6: ...red by regulated low voltage sources and electronics Caution Do not connect the NI 9205 to signals or use for measurements within Measurement Categories II III or IV Safety Guidelines for Hazardous Vo...

Страница 7: ...you must ensure that devices and circuits connected to the module are properly insulated from human contact You must use the NI 9940 connector backshell kit to ensure that the terminals are not access...

Страница 8: ...s unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components may impair suitability for Class I Division 2 Caution For Division 2 and Zone 2 applicat...

Страница 9: ...s you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 Ex IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment Caution You must make sure that transient disturbances do not exceed...

Страница 10: ...perational electromagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripher...

Страница 11: ...roduct visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install t...

Страница 12: ...0 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude NI 9205 with spring terminal 2 000 m NI 9205 with DSUB 5 000 m Indoor use only Note Refer to the...

Страница 13: ...the NI 9205 The NI 9205 provides connections for 32 single ended channels or 16 differential channels 12 ni com NI 9205 Getting Started Guide hnology Group Quality Instrumentation Guaranteed 888 88 S...

Страница 14: ...20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 AI0 AI1 AI2 AI3 AI4 AI5 AI6 AI7 AI16 AI17 AI18 AI19 AI20 AI21 AI22 AI23 COM DO0 AI8 AI9 AI10 AI11 AI12 AI13 AI14 AI15 AI24 AI25 AI26 AI27 AI28 AI...

Страница 15: ...nnel3 PFI Programmable function interface signal that functions as a digital input Signals You can connect single ended or differential signals to the NI 9205 Use a differential measurement configurat...

Страница 16: ...the NI 9205 Table 2 Differential Pairs Channel AI AI 0 AI0 AI8 1 AI1 AI9 2 AI2 AI10 3 AI3 AI11 4 AI4 AI12 5 AI5 AI13 6 AI6 AI14 7 AI7 AI15 16 AI16 AI24 17 AI17 AI25 NI 9205 Getting Started Guide Natio...

Страница 17: ...al Pairs Continued Channel AI AI 18 AI18 AI26 19 AI19 AI27 20 AI20 AI28 21 AI21 AI29 22 AI22 AI30 23 AI23 AI31 16 ni com NI 9205 Getting Started Guide hnology Group Quality Instrumentation Guaranteed...

Страница 18: ...Vcm AI0 CH0 AI8 CH0 AI1 CH1 AI9 CH1 COM V1 V2 In a differential configuration the NI 9205 rejects the common mode noise voltage Vcm during the measurement of V1 To connect grounded differential signal...

Страница 19: ...CH1 AI9 CH1 COM V1 V2 To connect floating differential signals to the NI 9205 you must connect the negative signal to COM through a 1 M resistor to keep the voltage within the maximum working voltage...

Страница 20: ...measures each channel with respect to COM To connect RSE signals to the NI 9205 you must connect the voltage ground signal to COM to keep the maximum working voltage in the specified range Note If you...

Страница 21: ...to the NI 9205 Figure 5 Connecting an RSE Voltage Signal to the NI 9205 NI 9205 MUX PGIA ADC V1 V2 COM AI1 AISENSE AI0 In an NRSE configuration the NI 9205 measures each channel with respect to AISENS...

Страница 22: ...following steps to connect wires to the spring terminal connector using the flathead screwdriver that is included with your C Series module or a flathead screwdriver with a blade smaller than 2 3 mm x...

Страница 23: ...clamp activation slot to open the corresponding connector terminal 2 Press a wire into the open connector terminal 3 Remove the screwdriver from the activation slot to clamp the wire into place 22 ni...

Страница 24: ...s subject to high vibration NI recommends that you use the NI 9940 backshell kit to protect connections to the NI 9205 with spring terminal NI 9205 Getting Started Guide National Instruments 23 hnolog...

Страница 25: ...INFORMATION Software Support Related Documentation ni com info softwareversion Services ni com services NI 9205 Datasheet NI RIO Help LabVIEW FPGA Help NI 9205 Datasheet NI DAQmx Help LabVIEW Help 24...

Страница 26: ...tes technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using t...

Страница 27: ...priate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements...