background image

©

 National Instruments Corporation

5

Getting Started with R Series Intelligent DAQ

Step 3. Connect Signals

Figure 4 shows the I/O connector pin assignments and locations for NI 781

x

R Digital R Series devices. 

Figure 5 shows the I/O connector pin assignments and locations for NI 783

x

R/784

x

R/785

x

Multifunction R Series devices.

Figure 4.  

NI 781

x

R Connector Pin Assignments and Locations

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

+5V

+5V

DIO2

8

DIO

3

1

DIO

33

DIO

3

5

DIO

3

7

DIO

3

9

DIO0

DIO2

DIO

3

DIO5

DIO6

DIO7

DIO

8

DIO1

DIO4

DIO9

DIO10

DIO11

DIO12

DIO1

3

DIO14

DIO15

DIO16

DIO17

DIO1

8

DIO19

DIO20

DIO21

DIO22

DIO2

3

DIO24

DIO25

DIO26

DIO27

DIO29

DIO

3

0

DIO

3

2

DIO

3

4

DIO

3

6

DIO

38

3

5

1

3

6

2

3

7

3

38

4

3

9

5

40

6

41

7

42

8

4

3

9

44 10

45 11

46 12

47 1

3

4

8

14

49 15

50 16

51 17

52 1

8

5

3

19

54 20

55 21

56 22

57 2

3

5

8

24

59 25

60 26

61 27

62 2

8

6

3

29

64

3

0

65

3

1

66

3

2

67

33

6

8 3

4

CONNECT

OR 1

(RDIO)

TERMINAL 

3

4

TERMINAL 6

8

TERMINAL 

3

5

TERMINAL 1

TERMINAL 

3

5

TERMINAL 1

TERMINAL 

3

4

TERMINAL 6

8

TERMINAL 

3

4

TERMINAL 6

8

TERMINAL 

3

5

TERMINAL 1

CONNECT

OR 0

(RDIO)

CONNECT

OR 2

(RDIO)

TERMINAL 

3

5

TERMINAL 1

TERMINAL 

3

4

TERMINAL 6

8

CONNECT

OR 

3

(RDIO)

Содержание R Series Intelligent DAQ PCI/PXI-783xR

Страница 1: ...omponents The following items are necessary to set up and use the NI PCI PXI 78xxR The following software packages LabVIEW LabVIEW FPGA Module NI RIO device drivers Optional LabVIEW Real Time Module R...

Страница 2: ...lable at ni com manuals In LabVIEW 8 0 or later you can also view the LabVIEW Manuals directory that contains these documents by selecting Start All Programs National Instruments LabVIEW LabVIEW Manua...

Страница 3: ...the Read Me First Safety and Radio Frequency Interference document packaged with your PXI chassis or device before removing equipment covers or connecting or disconnecting any signal wires 2 Remove t...

Страница 4: ...ace the computer cover if applicable 7 Plug in and power on the computer or PXI chassis To confirm that your device is recognized complete the following additional steps 1 Select Start All Programs Na...

Страница 5: ...ND DGND DGND 5V 5V DIO28 DIO31 DIO33 DIO35 DIO37 DIO39 DIO0 DIO2 DIO3 DIO5 DIO6 DIO7 DIO8 DIO1 DIO4 DIO9 DIO10 DIO11 DIO12 DIO13 DIO14 DIO15 DIO16 DIO17 DIO18 DIO19 DIO20 DIO21 DIO22 DIO23 DIO24 DIO25...

Страница 6: ...AI5 1 AIGND4 AI4 1 AI3 AIGND2 AI2 AI1 AIGND0 AI0 35 1 36 2 37 3 38 4 39 5 40 6 41 7 42 8 43 9 44 10 45 11 46 12 47 13 48 14 49 15 50 16 51 17 52 18 53 19 54 20 55 21 56 22 57 23 58 24 59 25 60 26 61...

Страница 7: ...SHC68 68 RMIO NI Recommended 0 NI SCB 68 High performance shielded cable wired specifically for signal connection from the RMIO connector to the NI SCB 68 terminal block to provide higher signal integ...

Страница 8: ...rojects designed to help you get started using your R Series device 4 Select Basic I O and then select Analog Input R Series lvproj 5 The Analog Input example project opens in the Project Explorer win...

Страница 9: ...e new target and click OK i In the Project Explorer window right click the original FPGA target and select Remove to delete it from the project j Save the project to a new directory by selecting File...

Страница 10: ...m the shortcut menu as shown in the following figure 2 In the Project Explorer window right click the FPGA target and select New FPGA I O 3 In the New FPGA I O dialog box expand Connector0 and select...

Страница 11: ...from the FPGA Interface palette between the Invoke method and the Read Write Control that already exists on the block diagram c Wire the FPGA VI Reference Out terminal of the Invoke Method node to the...

Страница 12: ...0 Where to Go From Here The following resources contain information for writing applications and taking measurements with R Series Intelligent DAQ devices LabVIEW FPGA documentation Getting Started wi...

Страница 13: ...To access the LabVIEW FPGA IPNet visit ni com ipnet Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to every...

Страница 14: ...Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appr...

Отзывы: