background image

1. Power off your PXI Express chassis, but leave it plugged in while installing the

PXIe-8267. The power cord grounds the chassis and protects it from electrical

damage while you install the module.

2. Locate an available PXI Express slot in the chassis. Do not install the PXIe-8267

in the controller slot (slot 1 in a PXI Express chassis).

3. Remove or open any doors or covers blocking access to the slot in which you

intend to install the PXIe-8267.

4. Touch the metal part of the case to discharge any static electricity that might

be on your clothes or body.

5. Make sure the injector/ejector handle is in its downward position. Be sure to

remove all connector packaging and protective caps from retaining screws on

the module. Align the PXIe-8267 with the card guides on the top and bottom

of the selected slot.

Note

 Do not raise the injector/ejector handle as you insert the

PXIe-8267. It will not insert properly unless the handle is in its

downward position so that it does not interfere with the injector/

ejector rail on the chassis.

6. Hold the handle as you slowly slide the module into the chassis until the

handle catches on the injector/ejector rail.

7. Raise the injector/ejector handle until the module firmly seats into the

backplane receptacle connectors. The front panel of the PXIe-8267 should be

even with the front panel of the chassis.

8. Tighten the bracket-retaining screws on the top and bottom of the front panel

to secure the PXIe-8267 to the chassis.

9. Replace or close any doors or covers to the chassis.

LED Indicators

The following table describes the PXIe-8267 front panel LEDs.

LED

Color

Meaning

Pwr/Fault

Off

Power is off

ni.com

6

PXIe-8267 Getting Started

Содержание PXIe-8267

Страница 1: ...PXIe 8267 Getting Started 2022 07 06...

Страница 2: ...eed to Get Started 3 Unpacking 3 Preparing the Environment 4 Hardware Installation 5 Software Driver Installation 7 RAID Creation 7 Moving the PXIe 8267 to a Different System 12 Optimizing Streaming P...

Страница 3: ...Code raidsupport Note The PXIe 8267 requires a chassis with slot cooling capacity 58 W Installation and Configuration This section explains how to unpack install and configure the PXIe 8267 hardware...

Страница 4: ...file a claim with the carrier Retain the packing material for possible inspection and or reshipment 4 Unpack any other items and documentation from the kit Preparing the Environment Ensure the enviro...

Страница 5: ...cations to determine the ambient temperature ranges your chassis can achieve 2 Drive utilization and storage temperatures will have an impact on unpowered data retention Visit ni com info and enter th...

Страница 6: ...8267 with the card guides on the top and bottom of the selected slot Note Do not raise the injector ejector handle as you insert the PXIe 8267 It will not insert properly unless the handle is in its d...

Страница 7: ...You must use the Disk Management Utility in Windows to manage the software RAID Note The PXIe 8267 supports only Windows 10 64 bit Note Refer to the drive manufacturer s website for information regard...

Страница 8: ...of the same size in basic mode If the disks do not have a status of Unallocated right click any disk and select Delete Partition 3 Right click any disk and select New Striped Volume then click Next 4...

Страница 9: ...5 Assign a drive letter and click Next National Instruments 9 PXIe 8267 Getting Started...

Страница 10: ...6 Configure the Format Volume page as shown in the following figure and click Next ni com 10 PXIe 8267 Getting Started...

Страница 11: ...7 Click Finish to close the New Striped Volume Wizard National Instruments 11 PXIe 8267 Getting Started...

Страница 12: ...igured in basic mode click Yes in the Disk Management dialog box to convert them to dynamic mode Note You must convert all disks that you want to include in the RAID array to dynamic mode ni com 12 PX...

Страница 13: ...ng to a different system is in software RAID mode Note To avoid data loss do not move swap or replace the drives 1 When the system boots go into Disk Management You will see four dynamic disks with ye...

Страница 14: ...he PXIe 8267 before you moved it to the new system Click OK to allow the new system to import the RAID volume The initial data is preserved and will be readable in the new system 4 Your RAID drive is...

Страница 15: ...agment and Optimize Drives tool and optimize the drives 4 When the operation completes recreate the striped array NI Services Visit ni com support to find support resources including documentation dow...

Отзывы: