background image

©

 National Instruments Corporation

3

NI PXIe-8115 Installation Guide

Figure 2 shows a NI PXIe-8115 controller installed in the system controller 
slot of a NI PXIe-1082 chassis.

Figure 2.  

NI PXIe-8115 Installed in a PXI Express Chassis

How to Remove the Controller from the PXI Express Chassis

The NI PXIe-8115 controller is designed for easy handling. To remove the 
unit from the PXI Express chassis:

1.

Power off the chassis.

2.

Remove any cables that may be attached to the controller front panel.

3.

Unscrew the 4 bracket-retaining screws in the front panel.

4.

Press the injector/ejector handle down.

5.

Slide the unit out of the chassis.

What If the NI PXIe-8115 Does Not Boot?

Several problems can cause a controller not to boot. Here are some things 
to look for and possible solutions.

Things to Notice

Which LEDs come on? The 

Power OK

 LED should stay lit. The 

Drive

 LED should blink during boot as the disk is accessed. 

What appears on the display? Does it hang at some particular point 
(BIOS, Operating System, etc.)? If nothing appears on the screen, try 
a different monitor. Does your monitor work with a different PC? If it 
hangs, note the last screen output that you saw for reference when 
consulting National Instruments technical support.

1

NI PXIe-1082 Chassis

2

NI PXIe-8115 Controller

3

Injector/Ejector Rail

1

3

2

Содержание PXIe-8115

Страница 1: ...fore installing the NI PXIe 8115 The power cord grounds the chassis and protects it from electrical damage while you install the module Make sure the power switch is turned off Cautions In some National Instruments chassis such as the NI PXIe 1082 you must ensure that the power LED is off For more information about chassis power behavior refer to the user manual for the specific chassis To protect...

Страница 2: ...n the four bracket retaining screws on the top and bottom of the front panel to secure the NI PXIe 8115 to the chassis 9 Check the installation 10 Connect the keyboard and mouse to the appropriate connectors If you are using a PS 2 keyboard and a PS 2 mouse a Y splitter adapter is available to connect both to a single USB connector National Instruments offers a Y splitter adapter cable part number...

Страница 3: ...l 4 Press the injector ejector handle down 5 Slide the unit out of the chassis What If the NI PXIe 8115 Does Not Boot Several problems can cause a controller not to boot Here are some things to look for and possible solutions Things to Notice Which LEDs come on The Power OK LED should stay lit The Drive LED should blink during boot as the disk is accessed What appears on the display Does it hang a...

Страница 4: ...dules from the chassis Remove any nonessential cables or devices Try the controller in a different chassis or a similar controller in this same chassis Clear the CMOS Refer to the System CMOS section of the NI PXIe 8115 User Manual Recover the hard drive on the controller Refer to the Hard Drive Recovery section of the NI PXIe 8115 User Manual For more troubleshooting information refer to the NI P...

Отзывы: