Страница 2: ...stalling the Software 8 Software Options 8 Installing the Software 8 Installing the NI 5663E 9 Interconnecting the NI 5663E Modules 10 Configuring the NI 5663E in MAX 18 Locating the Software and Exam...

Страница 3: ...Surface If the NI 5663E has been in use it may exceed safe handling temperatures and cause burns Allow the NI 5663E to cool before removing it from the chassis Electromagnetic Compatibility Guideline...

Страница 4: ...in requirements For more information about minimum system requirements recommended system and supported application development environments ADEs refer to the readme which is available on the software...

Страница 5: ...Store the device in the antistatic package when the device is not in use National Instruments 5 PXIe 5663E Getting Started...

Страница 6: ...Semi Rigid SMA to SMA Cable Labeled D Part Number 198776A 01 5 Medium Semi Rigid SMA to SMA Cable Labeled C Part Number 198775A 01 6 Flexible SMA to SMA Cable Part Number 190412B 03 7 SMA Driver Bit P...

Страница 7: ...ntation Optional Items A 1 N m standard SMA torque wrench NI part number 780487 01 Preparing the Environment Ensure that the environment you are using the NI 5663E in meets the following specification...

Страница 8: ...SA APIs each provide a fixed API for interacting with your NI 5663E device NI RFSA provides standard IVI based functionality needed for most vector signal analyzer applications Use NI RFSA to create c...

Страница 9: ...D or contamination handle the module using the edges or the metal bracket 1 Ensure the AC power source is connected to the chassis before installing the module The AC power cord grounds the chassis an...

Страница 10: ...ted 9 Latch the module in place by pulling up on the ejector handle 10 Secure the module front panel to the chassis using the front panel mounting screws Note Tightening the top and bottom mounting sc...

Страница 11: ...CESS ACTIVE C C D D 3 4 1 2 1 Medium Semi Rigid SMA to SMA Cable Labeled C 2 Flexible SMA to SMA Cable 3 Short Semi Rigid SMA to SMA Cable Labeled D 4 50 Termination Load 1 Using the center pin of a m...

Страница 12: ...for connections to external equipment may require torque different from 1 N m depending on the connector type material and manufacturer 6 Power on the PXI Express chassis and controller system 7 Verif...

Страница 13: ...20 dBm MAX 20 dBm MAX 20 dBm MAX 30 dBm MAX w Attenuation RF Downconverter Table 13 Device Front Panel Icon Definitions Refer to the user documentation for required maintenance measures to ensure use...

Страница 14: ...ation load to LO OUT Table 4 NI 5601 RF Downconverter Module Front Panel LEDs LED Indications ACCESS Indicates the basic hardware status of the module OFF The module is not yet functional or the modul...

Страница 15: ...input output ports can be damaged if subjected to ESD To prevent damage turn off power to the product before connecting cables and employ industry standard ESD prevention measures during installation...

Страница 16: ...Accessed means that the device setup registers are being written to in order to control the device GREEN The module is ready to be programmed by NI RFSA ACTIVE Indicates the module state OFF The modul...

Страница 17: ...it may exceed safe handling temperatures and cause burns Allow the device to cool before removing it from the chassis Table 9 NI 5652 RF Signal Generator Module Front Panel Connectors Connector Use RF...

Страница 18: ...shutdown condition Configuring the NI 5663E in MAX Use Measurement Automation Explorer MAX to configure your NI hardware MAX informs other programs about which NI hardware products are in the system a...

Страница 19: ...this step for all modules in your NI 5663E system The MAX self test performs a basic verification of hardware resources Software Locations Table 13 Locations of NI RFmx Software ADE Location LabVIEW A...

Страница 20: ...ivers niRFSA directory where IVIROOTDIR32 is one of the following locations Windows 10 32 bit 8 1 32 bit 7 32 bit Program Files IVI Foundation IVI Windows 10 64 bit 8 1 64 bit 7 64 bit Program Files x...

Страница 21: ...t Modular Instruments 4 Open the example that best matches your application requirements Using Microsoft Visual C C If you re using NI RFmx or NI RFSA with Microsoft Visual C C locate examples in the...

Страница 22: ...ht after you power on the chassis a problem may exist with the chassis power rails a hardware module or the LED Caution Apply external signals only while the NI 5663E is powered on Applying external s...

Страница 23: ...roller right click PCI to PCI Bridge and select Properties from the shortcut menu to verify that the bridge is enabled What Should I Do if the Module Fails the Self Test 1 Restart the system 2 Launch...

Страница 24: ...output terminals there may be a problem with the NI 5652 hardware Contact NI technical support or visit ni com support What Should I Do if the NI RFSA Soft Front Panel Does Not Launch 1 Verify the fr...

Страница 25: ...support resources including documentation downloads and troubleshooting and application development self help such as tutorials and examples Visit ni com services to learn about NI service offerings...