1.

Connect the cable center pin on the SMA cable to the SMA connector on the appropriate
device.

Note

 

Ensure that the SMA cable center pins properly align with the SMA

connectors to avoid bending the cable pins or damaging the front panel
connectors on the device. If the SMA cable does not exactly align with the
SMA connector, bend the cable slightly by hand to align the cable and the
connector. The amount of bending should be minimal. The cables can be
damaged by excessive bending.

2.

Hand-tighten the SMA cable end on the SMA connector after the cable center pins are
correctly aligned and connected. The cable connectors should tighten without much
torque or effort. If a cable bends due to incorrect alignment, remove the cable from the
front panel connector and repeat step 1 before continuing with this step.

3.

Use an appropriate torque wrench or torque screwdriver and SMA driver bit (not
included) to complete the tightening of the SMA cable to 1 N · m. Rotate the torque
wrench no more than one revolution to tighten the SMA cable before reaching maximum
torque.

Related Information

Refer to the PXIe-5696 Getting Started Guide for instructions about connecting the PXIe-5696
amplitude extender to your PXIe-5654.

Direct Connections to the PXIe-5654

The PXIe-5654 is a precision RF instrument that is sensitive to ESD and transients. Ensure
you take the following precautions when making direct connections to the PXIe-5654 to avoid
damaging the device.

Note

 

Do not apply external signals to the PXIe-5654. Applying external signals

may cause damage.

Ensure you are properly grounded when manipulating cables or antennas connected to the
PXIe-5654.

If you are using nonisolated devices, such as a nonisolated RF antenna, ensure the devices
are maintained in a static-free environment.

If you are using an active device, such as a preamplifier or switch routed to the
PXIe-5654, ensure no signal transients are sourced to the PXIe-5654.

PXIe-5654 Getting Started Guide

  | 

© National Instruments Corporation

  | 

7

Содержание PXIe-5654

Страница 1: ...ons et respectez toutes les mises en garde de la documentation d utilisation L utilisation du produit de toute autre fa on que celle sp cifi e risque de l endommager et de compromettre la protection d...

Страница 2: ...nuals for more information about minimum system requirements recommended system and supported application development environments ADEs Unpacking the Kit Notice To prevent electrostatic discharge ESD...

Страница 3: ...ce kit that you need to install or operate the PXIe 5654 Required Items A PXI Express chassis and chassis documentation The PXIe 1085 chassis is one available option for your device For more informati...

Страница 4: ...about installing removing and upgrading NI software using NI Package Manager 3 Follow the instructions in the installation prompts to install the NI RFSG driver software Note Windows users may see acc...

Страница 5: ...Chassis Compatibility Symbols 1 2 3 4 5 1 PXI Express System Controller Slot 2 PXI Peripheral Slot 3 PXI Express Hybrid Peripheral Slot 4 PXI Express System Timing Slot 5 PXI Express Peripheral Slot P...

Страница 6: ...els depending on your application Note For more information about installing slot blockers and filler panels go to ni com r pxiblocker 12 Power on the chassis Related Information Installing the Softwa...

Страница 7: ...ded to complete the tightening of the SMA cable to 1 N m Rotate the torque wrench no more than one revolution to tighten the SMA cable before reaching maximum torque Related Information Refer to the P...

Страница 8: ...2 dBm NOM REF OUT 2 100 MHz 5 dBm 2 dBm NOM TRIG IN OUT 3 3V CMOS IN OUT 0 5V MIN IN 5 5V MAX IN ESD SENSITIVE ALL PORTS 50 Table 1 Device Front Panel Icon Definitions Refer to the user documentation...

Страница 9: ...at accepts a modulating square wave to pulse the RF output FM IN Input terminal for frequency modulation AM IN Input terminal for amplitude modulation ALC IN Input terminal that connects to the ALC OU...

Страница 10: ...pand your Chassis tree item MAX lists all modules installed in the chassis Your default names may vary Note If you do not see your module listed press F5 to refresh the list of installed modules If th...

Страница 11: ...ation in Microsoft Visual C C Related Information Refer to the Getting Started topic of the NI RF Signal Generators Help for instructions about how to generate signals in a specific ADE Refer to the C...

Страница 12: ...NI RFSG SFP generates an error During signal generation the ACTIVE LED on the PXIe 5654 hardware module illuminates 5 Click RF On Off to stop signal generation Building a Basic NI RFSG Application Yo...

Страница 13: ...he VI front panel power level dBm control enter 0 In the frequency Hz control enter 100M 100 MHz 12 In the VI front panel resource name control enter the PXIe 5654 device name that you specified in MA...

Страница 14: ...output of the status element to an input of the Or function 9 Right click the unused input of the Or function and select Create Control to create a Boolean control 10 In the VI front panel right clic...

Страница 15: ...specified in MAX in the resource name control 4 Click the Run button on the toolbar to initiate sine wave generation 5 Click the VI front panel STOP button to stop sine wave generation You have succes...

Страница 16: ...it for damage Do not reinstall a damaged device 4 Reinstall the module in a different chassis slot 5 Power on the chassis 6 Verify that the device appears in MAX 7 Reset the device in MAX and perform...

Страница 17: ...downloads and troubleshooting and application development self help such as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and rep...

Страница 18: ...LAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how...

Отзывы: