2

|

ni.com

|

PXIe-4480/4481 Getting Started Guide

Caution

To ensure the specified EMC performance, operate this product only with 

shielded cables and accessories.

Caution

To ensure the specified EMC performance, the length of all mini-XLR 

cables must be no longer than 3 m (10 ft).

Caution

Electromagnetic interference can adversely affect the measurement 

accuracy of this product when used with BNC cables. The construction of a BNC 
coaxial cable is inherently unbalanced in that the outer conductor (LO) is used as a 
shield for the inner conductor (HI). However, for functional reasons, there is no input 
configuration of the PXIe-4480/4481 that directly connects the LO terminal to the 
chassis ground. Without a direct connection to chassis ground, the outer conductor 
does not act as a shield for unwanted noise and may act as an antenna for coupling 
noise into the module inputs. For single-ended measurements, the noise immunity for 
the system can be improved by directly connecting the outer conductor to the chassis 
or earth ground at the load end of the cable. For differential measurements, where 
such a connection is inherently not possible, the BNC cable can alternatively be 
wrapped in a separate grounded shield. In addition, you might need to use snap-on 
ferrite beads or other remedial measures to improve electromagnetic compatibility.

Unpacking the Kit

The PXIe-4480/4481 module ships in an antistatic package to prevent electrostatic discharge 
from damaging module components.

Caution

To prevent electrostatic discharge from damaging the device, ground 

yourself using a grounding strap or by holding a grounded object, such as your 
computer chassis.

1.

Touch the antistatic package to a metal part of the grounded object before removing the 
module from package.

2.

Remove the module from the package and inspect the module for loose components or any 
other sign of damage.

Caution

Never touch the exposed pins of connectors.

Store the device in the antistatic package when the device is not in use. Notify NI if the module 
appears damaged in any way; do not install a damaged device.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание PXIe-4480

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...s product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility EMC stated in the product specifications These requirements and limits provide reasonabl...

Страница 3: ...conductor to the chassis or earth ground at the load end of the cable For differential measurements where such a connection is inherently not possible the BNC cable can alternatively be wrapped in a s...

Страница 4: ...ons Verifying the Kit Contents The following items are necessary to set up and use the PXIe 4480 4481 PXIe 4480 4481 analog input module NI DAQmx installation media PXIe 4480 4481 Getting Started Guid...

Страница 5: ...acks for your operating system 3 Insert a compatible version of NI DAQmx To download the NI DAQmx driver visit ni com info and enter the Info Code daqmx 4 Follow the instructions in the installation p...

Страница 6: ...he chassis The PXIe 4480 4481 module can be placed only in the supported slot types identified in Table 1 Figure 1 shows the slot type symbols of the various slot types Refer to your chassis documenta...

Страница 7: ...l to the chassis using the front panel mounting screws Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis w...

Страница 8: ...all modules installed in the chassis Your default module names may vary Note If you do not see your hardware listed press F5 to refresh the list of installed modules If the module is still not listed...

Страница 9: ...S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 S17 S18 S19 S20 S21 S22 S23 S24 S25 S26 S27 S28 S29 S30 S31 S32 S33 S34 S35 S36 S37 S38 S39 S40 S41 S42 S43 S44 S45 S46 S47 S48 EX 0 EX 2 EX 3 EX 4 EX 5 EX 1 E...

Страница 10: ...able for signal names and descriptions and the correlation to the pin numbers of the BNC plug Table 2 RJ50 Connector Pin Assignments RJ50 Modular Plug Pin Number Diagram Pin Signal Name Signal Descrip...

Страница 11: ...l as other environmental information not included in this document Waste Electrical and Electronic Equipment WEEE EU Customers At the end of the product life cycle all products must be sent to a WEEE...

Страница 12: ...nufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certi...

Страница 13: ...ments EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy...

Страница 14: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: