background image

8

|

ni.com

|

NI PXIe-4339/TB-4339 Installation Guide and Terminal Block Specifications

Install the Terminal Block

Refer to Figure 5 to install the terminal block on the module while completing the following 
steps:
1.

Move the TB-4339/B/C into position in front of the NI PXIe-4339 and engage the 
alignment feature with the guide on the associated module.

Figure 5.  

Installing the TB-4339/B/C on the NI PXIe-4339 Module

2.

Attach the TB-4339/B/C to the NI PXIe-4339 module by pushing the terminal block 
straight into the module. A spring mechanism will lock in the bottom of the terminal block.

3.

Tighten the mounting screw at the top of the TB-4339/B/C to attach it to the NI PXIe-4339 
module.

Note

For safety purposes and to prevent damage to equipment when high voltages 

are present, all SC Express modules and terminal blocks are keyed to prevent 
connection between incompatible terminal blocks, modules, and/or cables.

4.

Power on the chassis.

1

NI PXIe Controller

2

NI PXIe Chassis

3

Mounting Screw

4

TB-4339/B/C Terminal Block

5

NI PXIe-4339 Module

6

Alignment Feature

NI PXIe-1062

Q

2

1

3

6

4

5

CO

OLI

NG

 CLE

AR

ANC

E A

ND

 FA

N F

ILTE

R M

AIN

TEN

ANC

E R

EQ

UIR

ED

S

EE 

MAN

UA

L.

CO

OLIN

G C

LEA

RANC

E A

ND 

FAN

 FILT

ER

 M

AINT

ENA

NCE

 RE

QU

IRE

D. 

S

EE M

ANU

AL.

Содержание PXIe-4339

Страница 1: ...nnecting to other modules that could be damaged by the voltage present on the terminal block However you should only use these terminal blocks with their supported modules Contents Electromagnetic Com...

Страница 2: ...ns when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television reception and pre...

Страница 3: ...tallation Install the Software Note You must be an administrator to install NI software and devices on your computer Ensure that the following software is installed before installing the SC Express ha...

Страница 4: ...rted PXI Express slot in the chassis SC Express devices can be placed only in PXI Express Peripheral slots PXI Express Hybrid Peripheral slots and PXI Express System Timing slots Refer to the chassis...

Страница 5: ...4 while completing the following steps Note You can find the pinout names and locations in Measurement Automation Explorer MAX at any time by right clicking the device name under Devices and Interfac...

Страница 6: ...to determine the function of the terminal The NI PXIe 4339 User Manual provides more detailed wiring information Make sure no exposed wire extends past the screw terminal Exposed wire increases the r...

Страница 7: ...raps to connect the shielded signal wires to the tie wrap holes for additional strain relief when necessary 10 Reinstall the top cover and tighten the captive top cover screws Note For information abo...

Страница 8: ...the bottom of the terminal block 3 Tighten the mounting screw at the top of the TB 4339 B C to attach it to the NI PXIe 4339 module Note For safety purposes and to prevent damage to equipment when hi...

Страница 9: ...annels and tasks and getting started developing an application For detailed NI software version support refer to the NI DAQmx Readme 1 Launch MAX 2 Expand Devices and Interfaces and expand the chassis...

Страница 10: ...ction for instructions for creating NI DAQmx simulated devices 3 Right click the module name and select Self Test When the self test completes a verification message appears If an error occurs refer t...

Страница 11: ...the DAQ Assistant in MAX Complete the following steps to create a task using the DAQ Assistant in MAX 1 In MAX right click Data Neighborhood and select Create New to open the DAQ Assistant 2 Select N...

Страница 12: ...ional examples refer to zone ni com Terminal Block Removal To remove the terminal block refer to Figure 7 while completing the following steps Note The chassis can be powered on or off when removing t...

Страница 13: ...so can damage the module To remove the module refer to Figure 8 while completing the following steps Note To maintain forced air cooling in the PXIe system refer to the Maintain Forced Air Cooling No...

Страница 14: ...c protective bag Figure 8 Removing SC Express Modules Create a Simulated Device To run examples without the hardware installed use an NI DAQmx simulated device To create a simulated device in MAX 1 La...

Страница 15: ...If you need to return your National Instruments hardware for repair or device calibration go to ni com info and enter rdsenn to start the Return Merchandise Authorization RMA process Specifications T...

Страница 16: ...free from contaminants before returning it to service Environmental Specifications Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use only Operating Environmen...

Страница 17: ...e requirements of MIL PRF 28800F Class 3 Safety Measurement Category I1 Caution Do not connect the TB 4339 B C to signals or use for measurements within Measurement Categories II III or IV Caution The...

Страница 18: ...aland per CISPR 11 Class A equipment is intended for use only in heavy industrial locations Note Group 1 equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentio...

Страница 19: ...nts website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assi...

Страница 20: ...s You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal expor...

Отзывы: