background image

© 

National Instruments Corporation

3

NI SIgnal Generators Getting Started Guide

This icon denotes a caution, which advises you of 
precautions to take to avoid injury, data loss, or a 
system crash. When this symbol is marked on the 
hardware product, refer to the 

Read Me First: 

Safety and Radio-Frequency Interference

 

document included with the device, for precautions 
to take.

bold

Bold text denotes items that you must select or click 
in the software, such as menu items and dialog box 
options.

italic

Italic text denotes emphasis or a cross-reference.

monospace

Text in this font denotes text or characters that you 
should enter from the keyboard, sections of code, 
programming examples, and syntax examples. This 
font is also used for disk drives, paths, directories, 
functions, filenames, and extensions.

monospace italic

Italic text in this font denotes text that is a 
placeholder for a word or value that you must 
supply.

Platform

Text in this font denotes a specific platform and 
indicates that the text following it applies only to 
that platform.

NI-DAQ

 

mx devices

The NI 5402/5404/5406/5412/5421/5422/ 
5441/5442 devices.

Traditional NI-DAQ

The NI 5401/5411/5431 devices.

(Legacy) devices

1. Verifying the System Requirements

To use an NI signal generator with NI-FGEN, your system must meet certain 
requirements. For more information on minimum system, recommended 
system, and supported application development environments (ADEs), refer 
to the 

NI-FGEN Instrument Driver Readme

, which is available on the 

NI-FGEN CDs. 

Note

After you install NI-FGEN, you can access the 

NI-FGEN Instrument Driver Readme

 at 

Start»All Programs»

National Instruments»NI-FGEN»Documentation

.

Содержание PXI-5421

Страница 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Страница 2: ...e for the NI FGEN instrument driver and information specific to your device For the NI signal generator specifications refer to the specifications document included with each device For free downloads...

Страница 3: ...30 NI PXIe 5442 32 Where to Go for Support 34 Conventions The following conventions are used in this manual The symbol leads you through nested menu items and dialog box options to a final action The...

Страница 4: ...for disk drives paths directories functions filenames and extensions monospace italic Italic text in this font denotes text that is a placeholder for a word or value that you must supply Platform Text...

Страница 5: ...install a damaged device into your computer Store the device in the antistatic envelope when not in use 3 Verifying the Kit Contents The following items are included in the NI signal generator kit NI...

Страница 6: ...XI Express chassis and chassis documentation A PXI Express controller or a MXI Express bridge For PCI devices A desktop computer with its documentation Note If your application uses NI TClk synchroniz...

Страница 7: ...the Hardware Caution You must power off and unplug the computer or chassis before installing the device To prevent damage to the device caused by ESD or contamination handle the device using the edges...

Страница 8: ...e has cooled to an acceptable operating temperature and has been reset successfully Installing PXI Modules To install the device in either a PXI chassis a PXI SCXI combination chassis or a PXI Compact...

Страница 9: ...8 Plug in the PXI chassis Uninstalling PXI Modules When removing PXI modules from the chassis ensure that you are grounded with a grounding strap or are touching a grounded metal surface To avoid ESD...

Страница 10: ...all the module in a PXI Express slot of a PXI Express chassis Refer to the chassis documentation to determine which slots are designated for PXI Express modules Figure 2 PXI Express Module Installatio...

Страница 11: ...te the following steps 1 Power off and unplug the PC 2 Remove the PC cover 3 Insert the device into an open PCI slot as shown in Figure 3 Figure 3 PCI Installation Tip To maximize airflow and extend t...

Страница 12: ...s for PXI and PCI Devices section for more information 6 Replace the PC cover 7 Plug in the PC 6 Power On Your Computer or PXI Chassis Windows recognizes any newly installed device the first time you...

Страница 13: ...x Devices folder Note If you are using a remote RT target expand Remote Systems find and expand your target and then expand Devices and Interfaces NI 5401 5411 5431 Expand Traditional NI DAQ Legacy De...

Страница 14: ...and indicates whether the device passed the test When the self test finishes a message indicates either successful verification or that an error occurred Note If the device does not pass the self tes...

Страница 15: ...uired for any type of synchronization including NI TClk synchronization involving an NI DAQmx device For information about NI TClk synchronization refer to Programming NI TClk Synchronization Help in...

Страница 16: ...Interfaces right click NI DAQmx Devices 3 Select Create New NI DAQmx Device RTSI Cable 4 To add a device to a RTSI cable right click on the RTSI cable name in the Configuration tree and select Add Dev...

Страница 17: ...m the drop down listbox Figure 5 Device Configuration Dialog Box 3 Click the Standard Function Mode button show in the following figure 4 Select the frequency amplitude offset and type of waveform tha...

Страница 18: ...ect Load Waveform from disk The Select File dialog box opens and displays waveform example files Note You also can download a waveform by selecting File Load New Waveform For the installation location...

Страница 19: ...on a bitmap image using the factory settings a Verify that the Device ID is set to the device number previously configured in MAX b Select Load BMP file and compute video data c Click Browse d Double...

Страница 20: ...Help NI FGEN Examples The NI FGEN examples demonstrate some of the functionality of the NI signal generators that you can use or integrate into your applications These examples serve as interactive to...

Страница 21: ...orms To view or edit existing waveforms you can open and resample data files saved in binary or ASCII file formats Once imported you can view and edit your waveforms You can also create new waveforms...

Страница 22: ...SMB connectors as shown in Figure 7 Signal descriptions for the NI PXI 5404 are listed in Table 1 The NI PCI 5401 has four connectors three SMB connectors and one 50 pin digital connector as shown in...

Страница 23: ...nal source and can frequency lock the NI PXI 5401 Sample clock timebase to the external Reference clock Table 2 NI PCI 5401 Front Panel Connectors Connector Access Function ARB Output Provides the wav...

Страница 24: ...generator The NI 5406 is a 40 MHz bandwidth 16 bit arbitrary function generator These devices have four BNC connectors as shown in Figure 8 Signal descriptions are listed in Table 3 Figure 8 NI PXI P...

Страница 25: ...e waveform being generated on CH 0 It can also be configured to accept a trigger from an external source that can start or step through waveform generation or can route signals out from several clock...

Страница 26: ...NI PXI 5404 The NI PXI 5404 is a 100 MHz frequency generator The NI PXI 5404 has five SMB connectors as shown in Figure 9 Signal descriptions are listed in Table 4 Figure 9 NI PXI 5404 Front Panel SIN...

Страница 27: ...ctor PFI 0 Input Output Accepts either a TTL signal to start waveform generation or provides an output to synchronize or trigger other devices at a certain time within waveform generation REF OUT Outp...

Страница 28: ...The NI PXI 5411 5431 has six connectors two BNC connectors three SMB connectors and one 50 pin digital connector as shown in Figure 10 Signal descriptions are listed in Table 5 Figure 10 NI PXI 5411...

Страница 29: ...e waveform being generated You can use this signal to synchronize or trigger other devices at a certain time within waveform generation PLL REF Input Accepts a PLL Reference clock from an external sou...

Страница 30: ...411 5431 Front Panel Connectors Connector Access Function ARB Output Provides the waveform output SYNC Output Provides a TTL level output of the waveform being generated at the ARB OUT connector PLL I...

Страница 31: ...generator The NI 5441 is a 100 MS s 43 MHz 16 bit arbitrary waveform generator with Onboard Signal Processing OSP These devices have up to five connectors four SMB connectors and one 68 pin male VHDC...

Страница 32: ...ut Accepts a trigger from an external source that can start or step through waveform generation or can route signals out from several clock event and trigger sources Refer to the NI Signal Generators...

Страница 33: ...ss 100 MS s 43 MHz 16 bit arbitrary waveform generator with Onboard Signal Processing OSP The NI 5442 has four SMB connectors as shown in Figure 13 Signal descriptions are listed in Table 8 Figure 13...

Страница 34: ...n also be used as a Sample clock source PFI 0 Input Output Accepts a trigger from an external source that can start or step through waveform generation or can route signals out from several clock even...

Страница 35: ...es located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or dial 512...

Страница 36: ...National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer t...

Страница 37: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: