background image

PXI-1000B AC Power Supply Shuttle Installation Guide

6

ni.com

Removal, Configuration, and Installation

This section describes how to remove, configure, and install your
PXI-1000B AC power supply shuttle.

Before connecting the power supply shuttle to a power source, read this
section and the

For Your Safety

section at the beginning of this document.

Removal

The PXI-1000B AC power supply shuttle is a replacement part for the
PXI-1000B AC chassis. Before attempting to replace the power supply
shuttle, verify that there is adequate clearance behind the chassis. Set the
power switch on the front panel to the Standby position and disconnect the
power cord from the power supply shuttle on the back of the chassis.
Identify the six captive screws that attach the power supply shuttle to the
chassis. Using a Phillips screwdriver, loosen the captive screws. Pull on the
handles of the original power supply shuttle to remove it from the back of
the chassis.

Configuration

The fan speed selector switch is on the rear panel of the power supply
shuttle. See Figure for the fan speed selector location. Select HI for
maximum cooling effectiveness (recommended) or LO for quiet operation.

Installation

Ensure that there is no visible damage to the new power supply shuttle.
Verify that the frame and connector on the new power supply shuttle have
no foreign material inside. Install the new power supply shuttle into the
opening on the rear of the chassis. Tighten the six captive screws with a
Phillips screwdriver.

Содержание PXI 1000B

Страница 1: ...GUIDE PXI 1000B AC POWER SUPPLY SHUTTLE Contents Important Information 2 For Your Safety 3 Getting Started 4 Unpacking 4 What You Need to Get Started 4 Key Features 4 Removal Configuration and Instal...

Страница 2: ...wner s modification of the product owner s abuse misuse or negligent acts and power failure or surges fire flood accident actions of third parties or other events outside reasonable control Copyright...

Страница 3: ...he PXI 1000B AC power supply shuttle Adjustments and service to internal components must be undertaken by qualified service technicians During service of this product the mains connector to the premis...

Страница 4: ...items PXI 1000B AC power supply shuttle assembly This installation guide You must provide an AC power cable See Table 1 for a list of cables Key Features The PXI 1000B AC power supply shuttle combines...

Страница 5: ...power supply shuttle Figure 2 shows a rear view Figure 1 Isometric View of the PXI 1000B AC Power Supply Shuttle Figure 2 Rear View of the PXI 1000B AC Power Supply Shuttle 1 Module Cooling Air Outle...

Страница 6: ...rd from the power supply shuttle on the back of the chassis Identify the six captive screws that attach the power supply shuttle to the chassis Using a Phillips screwdriver loosen the captive screws P...

Страница 7: ...rs or a toothed lug Connecting to Power Source and Testing Power Up Caution Remove all PXI modules from the PXI 1000B chassis prior to performing the first power on test 1 Attach the appropriate power...

Страница 8: ...PXI 1000B AC power supply shuttle supports remote power monitoring and inhibiting via a 9 pin D sub connector on the rear panel Table 3 shows the pinout of the DB 9 connector Table 2 Power Supply Volt...

Страница 9: ...ths Depending on the amount of use and ambient dust levels in the operating environment the filters may require more frequent cleaning Clean dust from the exterior and interior as needed based on the...

Страница 10: ...st enough moisture to dampen the cloth Do not wash the rear panel connectors or switches Cover these components while cleaning the power supply shuttle Do not use chemical cleaning agents they may dam...

Страница 11: ......

Страница 12: ......

Отзывы: