Getting Started with the NI PCI-8254R

2

ni.com

LED ringlight and constant current source (part number 778787-01)

12 mm fixed focal length lens (part number 778789-01)

Refer to the National Instruments catalog, visit 

ni.com

, or call the National Instruments office nearest 

you for more specific information about these products

Related Documentation

The following documents contain additional information that you may find helpful:

NI PCI-8254R User Manual

—Contains information about programming options, hardware 

functionality, and signal connections.

NI Vision Acquisition Software Release Notes

—Contains information about new functionality, 

minimum system requirements, and installation instructions for the NI-IMAQdx driver software.

Measurement & Automation Explorer Help for NI-IMAQdx

—Describes how to configure 

NI-IMAQdx driver software, NI image acquisition devices, and cameras using Measurement & 
Automation Explorer (MAX).

NI-IMAQdx User Manual

—Contains fundamental programming concepts for the NI-IMAQdx 

driver software and terminology for using NI image acquisition devices.

LabVIEW Help

—This document contains reference information for the NI-IMAQ I/O shutdown 

states VIs, terminal references for the configurable I/O module on the NI-IMAQ I/O device, and 
parameter references for the parameters you can set for the NI-IMAQ I/O device in the Read/Write 
control. To locate the information, search for 

NI-IMAQ I/O

 in the 

LabVIEW Help

.

Safety Information

Caution

The following paragraphs contain important safety information you 

must

 follow when 

installing and operating the device.

Do 

not

 operate the device in a manner not specified in the documentation. Misuse of the device may 

result in a hazard and may compromise the safety protection built into the device. If the device is 
damaged, turn it off and do 

not

 use it until service-trained personnel can check its safety. If necessary, 

return the device to National Instruments for repair.

Keep away from live circuits. Do 

not

 remove equipment covers or shields unless you are trained to do 

so. If signal wires are connected to the device, hazardous voltages can exist even when the equipment is 
turned off. To avoid a shock hazard, do 

not

 perform procedures involving cover or shield removal unless 

you are qualified to do so. Disconnect all field power prior to removing covers or shields.

If the device is rated for use with hazardous voltages (>30 V

rms

, 42.4 V

pk

, or 60 V

dc

), it may require a 

safety earth-ground connection wire. Refer to the device specifications for maximum voltage ratings.

Because of the danger of introducing additional hazards, do 

not

 install unauthorized parts or modify

the device. Use the device only with the chassis, modules, accessories, and cables specified in the 
installation instructions. All covers and filler panels 

must

 be installed while operating the device.

Do 

not

 operate the device in an explosive atmosphere or where flammable gases or fumes may be 

present. Operate the device only at or below the pollution degree stated in the specifications. Pollution 

Содержание NI VISION PCI-8254R

Страница 1: ...PCI 8254R...

Страница 2: ...ndows Vista NI Vision Acquisition Software 8 2 1 or later which includes the NI IMAQdx and NI IMAQ I O driver software Optional software for developing applications NI Vision Builder for Automated Ins...

Страница 3: ...he LabVIEW Help Safety Information Caution The following paragraphs contain important safety information you must follow when installing and operating the device Do not operate the device in a manner...

Страница 4: ...lse withstand voltage levels that commonly occur in electrical distribution systems The following is a description of Measurement Installation3 Categories Measurement Category I is for measurements pe...

Страница 5: ...uter Store the NI 8254R in the antistatic package when not in use Installation The following instructions are for general installation Refer to the documentation provided by your computer manufacturer...

Страница 6: ...o an IEEE 1394a connector on the NI 8254R front panel Refer to Figure 1 for the location of the IEEE 1394a connectors on the NI 8254R 12 Plug in and power on the computer The NI 8254R is now installed...

Страница 7: ...Figure 3 b Reconnect the wire that was connected to the C position on the 4 position power connector to the C position on the 2 position isolated outputs power connector shown in Figure 3 Figure 2 Rem...

Страница 8: ...power supply cable around the ferrite two times as shown in Figures 4 and 5 Figure 4 Installing a Ferrite Connector on the Power Supply Cable Figure 5 Closed Ferrite on the Power Supply Cable 4 Plug t...

Страница 9: ...cturer specifications to terminate the wires leading to the 2 position power connector shown in Figure 7 Ferrules are available from Phoenix Contact part number 3200519 Figure 7 Wiring a Third Party P...

Страница 10: ...orer MAX the National Instruments configuration utility to configure the IEEE 1394 camera connected to the NI 8254R for acquisition Refer to the Measurement Automation Explorer Help for NI IMAQdx for...

Страница 11: ...Hz maximum load resistance 100 k Minimum pulse generated 100 s Reverse polarity protection Yes IEEE 1394 Number of ports 2 Speed 100 200 or 400 Mbps Power Requirements IEEE 1394 bus power1 18 W maximu...

Страница 12: ...electrical equipment for measurement control and laboratory use EN 61326 EMC requirements Minimum Immunity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For...

Страница 13: ...ts calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 787...

Отзывы: