Getting Started with the NI CVS-1450 Series
Figure 2.
Basic Hardware Setup
Wiring Power to the NI CVS-1450 Device
This section describes how to connect the NI desktop power supply. For instructions on how to connect
a separate main supply, refer to the
Connecting to a Separate Main Supply
Caution
Do
not
connect the NI CVS-1450 device main power to a source other than 24 VDC ±10%.
Do
not
connect the NI CVS-1450 device isolated power to a source less than 5 VDC or greater than
30 VDC. Doing so could damage the NI CVS-1450 device.
To connect power to the NI CVS-1450 device, refer to Figure 3 while completing the following steps:
1.
Plug the 4-position connector from the power supply into the power receptacle on the
NI CVS-1450 device.
2.
Plug the power cord into the power supply.
3.
Plug the power cord into an outlet.
The NI CVS-1450 device ships with a factory-installed startup program that, when the NI CVS-1450
device is connected to a camera and powered on, acquires images and displays them on the monitor.
If the images from the camera display on the monitor, continue to the
section. If the images from the camera are not displayed on the monitor, refer to
the
NI CVS-1450 Series User Manual
for troubleshooting information.
1
VGA Cable
2
IEEE 1394 Cable
1
2