Chapter 2
Using the SCXI-1129
2-26
ni.com
Figure 2-16.
Wire ORed Operation
Software Scanning
Unlike hardware-timed scanning, software scanning does not use
hardware-generated triggers. In software scanning, a list of matrix
configurations, kept by the software, is scanned by selecting the desired
configuration on the SCXI-1129 and making the required measurements.
Refer to the
NI-SWITCH Software User Manual
for more information on
software scanning.
Independent Switch Control
You can independently control all 276 relays on the SCXI-1129, including
connection relays and HVAB relays. To close/open the relays, refer to them
by their appropriate name. Refer to Table 2-3.
Note
Independent switch control is valid only in the 4
×
16 configuration.
Backplane
Connector
HVAB
RSC
Front Connector
Backplane
Connector
Front Connector
SCXI-1129
Backplane
Connector
Front Connector
SCXI-1129
Trig 0
Trig 1
Trig 6
Trig 7
•
•
•
Backplane
Cabled SCXI-1129
EXTTRIGIN
from DMM VMC
SCANADVD
To DMM
VMC
SCANADVD
Содержание NI SCXI-1336
Страница 1: ...SCXI 1336...