![National Instruments NI sbRIO-9627 Скачать руководство пользователя страница 11](http://html2.mh-extra.com/html/national-instruments/ni-sbrio-9627/ni-sbrio-9627_specification_3454010011.webp)
Design Guide
on
ni.com/manuals
for more information about how to power the NI sbRIO
device through the RMC.
Caution
Exceeding the power limits may cause unpredictable device behavior.
Recommended power supply
55 W, 30 VDC maximum
Power supply voltage range
9 VDC to 30 VDC
Reversed-voltage protection
30 VDC
Power consumption with RMC
29 W maximum
Environmental
Caution
Clean the sbRIO-9627 with a soft, nonmetallic brush. Make sure that the
device is completely dry and free from contaminants before returning it to service.
Local ambient operating temperature near
device (IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 85 °C
10
Maximum reported onboard sensor temperature
CPU/FPGA temperature
98 °C
Primary System temperature
85 °C
Secondary System temperature
85 °C
Table 1. Component Maximum Case Temperature
Component
Manufacturer
Maximum Case Temperature
CPU/FPGA
Xilinx
NA
11
DDR memory
Micron
95 °C
NAND flash
Micron
89 °C
CPLD
Lattice
94 °C
USB PHY
Microchip
120 °C
ENET PHY
Micrel
120 °C
The sbRIO-9627 includes three onboard temperature monitoring sensors to simplify validation
of a thermal solution by indicating thermal performance during validation and deployment.
10
If you expect ambient temperatures below -20 °C, NI recommends using a 10/100 network
infrastructure or assigning 10/100Mbps communication speeds to the Ethernet Adapter in NI MAX.
Refer to the
Network/Ethernet Port
section of this document for more information.
11
Use digital approach to ensure the on-chip temperature reading is below 98°C.
NI sbRIO-9627 Specifications
|
© National Instruments
|
11