Getting Started with the NI PXI/PCI-1428

2

ni.com

Related Documentation

The following documents contain additional information that you may find helpful:

NI PXI/PCI-1428 User Manual

—Contains information about programming options, hardware 

functionality, and signal connections.

NI Vision Acquisition Software Release Notes

—Contains information about new functionality, 

minimum system requirements, and installation instructions for the NI-IMAQ driver software.

Measurement & Automation Explorer Help for NI-IMAQ

—Describes how to configure the 

NI-IMAQ driver software, NI image acquisition devices, and cameras using Measurement & 
Automation Explorer (MAX).

NI-IMAQ Help

—Contains fundamental programming concepts for the NI-IMAQ driver software 

and terminology for using NI image acquisition devices.

Safety Information

Caution

The following paragraphs contain important safety information you 

must

 follow when 

installing and operating the device.

Do 

not

 operate the device in a manner not specified in the documentation. Misuse of the device may 

result in a hazard and may compromise the safety protection built into the device. If the device is 
damaged, turn it off and do 

not

 use it until service-trained personnel can check its safety. If necessary, 

return the device to National Instruments for repair.

Keep away from live circuits. Do 

not

 remove equipment covers or shields unless you are trained to do 

so. If signal wires are connected to the device, hazardous voltages can exist even when the equipment is 
turned off. To avoid a shock hazard, do 

not

 perform procedures involving cover or shield removal unless 

you are qualified to do so. Disconnect all field power prior to removing covers or shields.

If the device is rated for use with hazardous voltages (>30 V

rms

, 42.4 V

pk

, or 60 V

dc

), it may require a 

safety earth-ground connection wire. Refer to the device specifications for maximum voltage ratings.

Because of the danger of introducing additional hazards, do 

not

 install unauthorized parts or modify the 

device. Use the device only with the chassis, modules, accessories, and cables specified in the 
installation instructions. All covers and filler panels 

must

 be installed while operating the device.

Do 

not

 operate the device in an explosive atmosphere or where flammable gases or fumes may be 

present. Operate the device only at or below the pollution degree stated in the specifications. Pollution 
consists of any foreign matter—solid, liquid, or gas—that may reduce dielectric strength or surface 
resistivity. The following is a description of pollution degrees.

Pollution Degree 1—No pollution or only dry, nonconductive pollution occurs. The pollution has 
no effect.

Pollution Degree 2—Normally only nonconductive pollution occurs. Occasionally, nonconductive 
pollution becomes conductive because of condensation.

Pollution Degree 3—Conductive pollution or dry, nonconductive pollution occurs. Nonconductive 
pollution becomes conductive because of condensation.

Clean the device and accessories by brushing off light dust with a soft, nonmetallic brush. Remove other 
contaminants with a stiff, nonmetallic brush. The unit 

must

 be completely dry and free from 

contaminants before returning it to service.

Содержание NI PXI/PCI-1428

Страница 1: ...ision Acquisition Software 8 2 0 or later which includes the NI IMAQ driver software Optional software for developing applications NI Vision Builder for Automated Inspection NI Vision Development Module LabVIEW LabWindows CVI Microsoft Visual Basic Optional Equipment National Instruments offers a variety of products for use with the NI 1428 including the following NI D6804 breakout cable used for ...

Страница 2: ...ent is turned off To avoid a shock hazard do not perform procedures involving cover or shield removal unless you are qualified to do so Disconnect all field power prior to removing covers or shields If the device is rated for use with hazardous voltages 30 Vrms 42 4 Vpk or 60 Vdc it may require a safety earth ground connection wire Refer to the device specifications for maximum voltage ratings Bec...

Страница 3: ...Measurement Category II are measurements performed on household appliances portable tools and similar products Measurement Category III is for measurements performed in the building installation at the distribution level This category refers to measurements on hard wired equipment such as equipment in fixed installations distribution boards and circuit breakers Other examples are wiring including ...

Страница 4: ...ls of the PXI or CompactPCI chassis 8 Connect the MDR 26 pin Camera Link cable to the camera Refer to your camera manufacturer documentation for specific instructions about how to connect the cable to your camera 9 Connect the Camera Link cable to the Camera Link connector on the NI PXI 1428 front panel 10 Plug in and power on the PXI or CompactPCI chassis The NI PXI 1428 is now installed and the ...

Страница 5: ...a_model icd supplied by National Instruments The NI IMAQ driver software uses the information in this camera file to program the NI 1428 to acquire images from a specific camera Without this camera file the driver does not have the information necessary to configure the NI 1428 to recognize the image format of the particular camera you are using Refer to MAX for information about valid camera attr...

Страница 6: ...55 V at 10 mA sink Polarity Programmable active high or active low Power on state Input high impedance 10 KΩ pull up to 5 V Pixel clock Camera Link compatible Enables Camera Link compatible Control signal Camera Link compatible Video data Camera Link compatible Clocks Pixel clock frequency range 20 MHz to 50 MHz Note Camera Link cameras must transmit at a minimum of 20 MHz 1 PCI Interface Theoreti...

Страница 7: ...line and click the appropriate link in the Certification column Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement control and laboratory use EN 61326 EMC requirements Minimum Immunity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance ope...

Страница 8: ... compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the wo...

Отзывы: