Chapter 12
Synchronization
©
National Instruments Corporation
12-17
Periodic Breakpoints (NI 7350 only)
Periodic breakpoints require that you specify an initial breakpoint and an
ongoing repeat period. When enabled, the periodic breakpoints begin when
the initial breakpoint occurs. From then on, a new breakpoint occurs each
time the axis moves a distance equal to the repeat period, with no
re-enabling required.
For example, if an axis is enabled at position zero, the initial breakpoint is
set for position 100, and the breakpoint period is set at 1,000, then the axis
behaves as shown in Figure 12-8.
Figure 12-8.
Periodic Breakpoint Every 1,000 Counts/Steps
Periodic Breakpoint Algorithm
Figure 12-9 shows the basic algorithm for periodic breakpoints.
Figure 12-9.
Periodic Breakpoint Algorithm
1100
2100
100
3100
= Breakpoint
= Armed Breakpoint
= Current Position
Direction
–900
Configure breakpoint
Enable breakpoint
Load breakpoint bosition
Load the initial breakpoint
Load breakpoint modulus
Load the breakpoint period