National Instruments Corporation
23
MID-7604/7602 Power Drive User Guide
Panel-Mount Kit (Included)
The panel-mount kit allows you to mount the MID-7604/7602 inside a
cabinet or enclosure. Using the provided screws, attach the panel-mount kit
to the rear and front set of screw holes on the side panels of the
MID-7604/7602, as shown in Figure 16.
Figure 16.
MID-7604/7602 with the Panel-Mount Kit Installed
Note
The strain-relief bar and panel-mount kit cannot be installed at the same time.
Amplifier/Driver Command Signals
For stepper drivers, the two industry standards for command signals are
as follows:
•
Step and Direction signals (MID-7604/7602 standard)
•
Independent CW and CCW pulses
The MID-7604/7602 uses stepper drivers that have active high step and
direction inputs. You must configure the stepper outputs of your motion
controller for Step and Direction signals with active high polarity.
Note
You can use National Instruments Measurement & Automation Explorer (MAX) to
configure the stepper polarity for your NI motion controller.
Panel-Mount Bracket