manualshive.com logo in svg
background image

Getting Started with the NI EVS-1464RT

8

ni.com

NI Vision Builder for Automated Inspection

 (Vision Builder AI)—Interactive, menu-driven 

configuration software for developing, benchmarking, and deploying machine vision applications.

To use Vision Builder AI to configure the NI EVS-1464RT and develop your application, complete 
the instructions in the 

Configuring the NI EVS-1464RT with Vision Builder AI

 section of this 

document.

NI LabVIEW

—Graphical programming environment for developing flexible and scalable 

applications. The following add-on modules are required to develop machine vision applications 
for the NI EVS-1464RT:

NI LabVIEW Real-Time Module

—Programming library for developing distributed, 

deterministic applications.

NI Vision Development Module

—Programming library for developing machine vision and 

scientific imaging applications.

NI Vision Acquisition Software

—Includes programming libraries for acquiring images and 

controlling I/O using the NI EVS-1464RT.

To use LabVIEW to develop your application, you must use Measurement & Automation Explorer 
(MAX)—the National Instruments configuration utility—to configure the NI EVS-1464RT. To use 
MAX to configure the NI EVS-1464RT, complete the instructions in the 

Configuring the 

NI EVS-1464RT with MAX

 section of this document.

Installing NI Vision Acquisition Software

The latest version of NI Vision Acquisition software is included with the NI EVS-1464RT. NI Vision 
Acquisition Software includes driver software and MAX—the National Instruments configuration 
utility—which you can use to configure the NI EVS-1464RT.

Complete the following instructions to install NI Vision Acquisition Software:

1.

Insert the NI Vision Acquisition Software DVD.

2.

When the installation screen appears, click 

Install NI Vision Acquisition Software

, and follow 

the setup instructions.

To use MAX to configure the NI EVS-1464RT, complete the instructions in the 

Configuring the 

NI EVS-1464RT with MAX

 section of this document.

Note

If you plan to use LabVIEW to develop applications, install LabVIEW before installing 

NI Vision Acquisition Software.

Connecting the NI EVS-1464RT to the Development Computer

To configure the NI EVS-1464RT, you must connect the NI EVS-1464RT to a development computer. 
The NI EVS-1464RT can connect to the development computer directly or through a network using an 
Ethernet cable.

Vi

s

ion B

u

ilder

for

A

u

tom

a

ted In

s

pection

L

ab

VIEW

L

ab

VIEW Re

a

l-Time Mod

u

le

NI Vi

s

ion Development Mod

u

le

NI Vi

s

ion Acq

u

i

s

ition 

S

oftw

a

re

or

Содержание NI EVS-1464RT

Страница 1: ...1464RT kit the following components are necessary to set up and configure the NI EVS 1464RT One of the following power supply options Caution Use the NI EVS 1464RT only with a 24 VDC UL listed limite...

Страница 2: ...t ni com or call the National Instruments office nearest you for more specific information about these products Safety Information The following section contains important safety information that you...

Страница 3: ...ses overvoltage from the circuit to which they are connected during measurement or test Measurement categories establish standard impulse withstand voltage levels that commonly occur in electrical dis...

Страница 4: ...radio communications services or other nearby electronics which can be determined by turning the hardware off and on you are encouraged to try to correct the interference by one or more of the follow...

Страница 5: ...in or unplugging any connector Ground the unit to minimize the possibility of static electricity damage Refer to Figure 1 while completing the following steps to install the NI EVS 1464RT Figure 1 NI...

Страница 6: ...ion Cameras Connect the camera Ethernet cable to the secondary network connector on the NI EVS 1464RT front panel The camera is now attached to the NI EVS 1464RT Connecting the Power Supply To connect...

Страница 7: ...power supply cord into an outlet The orange ISO LED on the NI EVS 1464RT front panel will illuminate when the computer is on and an isolated power supply is properly connected Configuring the Developm...

Страница 8: ...T To use MAX to configure the NI EVS 1464RT complete the instructions in the Configuring the NI EVS 1464RT with MAX section of this document Installing NI Vision Acquisition Software The latest versio...

Страница 9: ...4RT The NI EVS 1464RT automatically attempts to detect the presence of a network If a DHCP server is not available the NI EVS 1464RT uses a link local address to connect directly to the development co...

Страница 10: ...ied to it The NI EVS 1464RT is now connected to the development computer through a network Configuring the NI EVS 1464RT for Deployment The following sections describe how to use the application devel...

Страница 11: ...t the NI EVS 1464RT with a MAC address that corresponds to the MAC address on the bottom label of the NI EVS 1464RT you want to configure Refer to Appendix D Common Questions of the NI EVS 1464 Series...

Страница 12: ...Vision Builder AI RT Images directory where Vision Builder AI is the location where Vision Builder AI is installed 4 Click OK to apply the IP configuration settings and download software to the NI EVS...

Страница 13: ...l Programs National Instruments Measurement Automation 2 Expand the Remote Systems branch of the configuration tree and select the device you want to configure Refer to Appendix D Common Questions of...

Страница 14: ...ttings to open the Advanced Ethernet Settings dialog box 4 Select the MAC address for the secondary Ethernet connector from the Ethernet Devices list 5 Select TCP IP Network in the Mode list 6 Manuall...

Страница 15: ...464RT systems are intended for indoor use only Maximum altitude 2 000 m Pollution Degree IEC 60664 2 Operating Environment Ambient temperature range 0 C to 45 C IEC 60068 2 1 and IEC 60068 2 2 Relativ...

Страница 16: ...ctive safety 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To...

Страница 17: ...I Documentation You can also access context help within Vision Builder AI by clicking the Show Context Help button on the Vision Builder AI toolbar Examples of common Vision Builder AI inspections are...

Страница 18: ...calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also...

Страница 19: ...ther product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate locat...

Отзывы: