background image

Connecting the cRIO-9036 to the Host Computer or
Network Using Ethernet

Complete the following steps to connect the cRIO-9036 to a host computer or Ethernet
network using the RJ-45 Gigabit Ethernet port 1. NI recommends using the RJ-45 Gigabit
Ethernet port 1 for communication with deployed systems.

Note

 

You can configure the RJ-45 Gigabit Ethernet port 2 in Measurement &

Automation Explorer (MAX) under the 

Network Settings

 tab.

1.

Power on the host computer or Ethernet hub.

2.

Connect the RJ-45 Gigabit Ethernet port 1 on the cRIO-9036 to the host computer or
Ethernet hub using a standard Category 5 (CAT-5) or better shielded, twisted-pair
Ethernet cable.

Caution

 

To prevent data loss and to maintain the integrity of your Ethernet

installation, do not use a cable longer than 100 m (328 ft).

The cRIO-9036 attempts to initiate a DHCP network connection the first time you
connect using Ethernet. The cRIO-9036 connects to the network with a link-local IP
address with the form 169.254.

x

.

x

 if it is unable to initiate a DHCP connection.

Finding the cRIO-9036 on the Network (DHCP)

Complete the following steps to find the cRIO-9036 on a network using DHCP.
1.

Disable secondary network interfaces on the host computer, such as a wireless access
card on a laptop.

2.

Ensure that any anti-virus and firewall software running on the host computer allows
connections to the host computer.

Note

 

MAX uses UDP 44525. Refer to the documentation of your firewall

software for information about configuring the firewall to allow communication
through the UDP 44525.

3.

Launch MAX on the host computer.

4.

Expand 

Remote Systems

 in the configuration tree and locate your system.

Tip

 

MAX lists the system under the model number followed by the serial

number, such as NI-cRIO-9036-1856AAA.

Finding the cRIO-9036 on the Network (Static IP)

Complete the following steps to find the cRIO-9036 on the network if the host computer is
using a static IP address. The following instructions are for host computers running
Windows 7. For more information about performing the network configuration steps in this
section, visit 

www.microsoft.com

 and search for 

change tcp/ip settings

.

1.

Obtain IP settings from the host computer.
a)

Click 

Start»Control Panel»Network and Sharing Center

.

b)

Select the primary network connection, which may appear as 

Local Area

Connection

 or something similar.

NI cRIO-9036 User Manual

  | 

© National Instruments

  | 

3

Содержание NI cRIO-9036

Страница 1: ...unting and operating the device USB 2 0 Host Port USB 2 0 Device Port 1 GB DDR3L RJ 50 RS 232 Serial Port RJ 50 RS 485 422 DTE Serial Port SD Card Slot Intel Atom E3825 1 33 GHz Dual Core System On Ch...

Страница 2: ...29 Mounting the Device on a Rack 31 Mounting the Device on a Desktop 31 BIOS Configuration 32 Resetting the System CMOS and BIOS Settings 32 Power On Self Test Warning Messages 33 BIOS Setup Utility...

Страница 3: ...g steps to find the cRIO 9036 on a network using DHCP 1 Disable secondary network interfaces on the host computer such as a wireless access card on a laptop 2 Ensure that any anti virus and firewall s...

Страница 4: ...bottom of the window d Select Static on the Configure IPv4 Address control e Enter values for IPv4 Address Subnet Mask Gateway and DNS Server based on the information you recorded Be sure to enter a...

Страница 5: ...ing on prevents any LabVIEW startup applications from running Disable FPGA Startup App Rebooting the cRIO 9036 with this setting on prevents autoloading of any FPGA application Enable Secure Shell SSH...

Страница 6: ...Removable Storage 4 RS 232 Serial Port 5 RS 485 422 DTE Serial Port 6 Mini DisplayPort 7 USB Host Ports 8 USB Device Port RJ 45 Gigabit Ethernet Ports The cRIO 9036 has two tri speed RJ 45 Gigabit Eth...

Страница 7: ...ossover cable to connect to a host computer The following NI Ethernet cables are available for the cRIO 9036 Table 3 RJ 45 Gigabit Ethernet Cables Cables Length Part Number CAT 5E Ethernet Cable shiel...

Страница 8: ...nd V2 inputs the cRIO 9036 operates from the V1 input If the input voltage to V1 is insufficient the cRIO 9036 operates from the V2 input The cRIO 9036 has reverse voltage protection The following NI...

Страница 9: ...shing or lit because file corruption may result Note Screw the slot cover closed completely Tighten the captive screws to a maximum torque of 0 75 N m 6 7 lb in using a 1 Phillips screwdriver Do not o...

Страница 10: ...h Part Number RS 232 S8 Serial Cable 10 Position Modular Plug to 9 Pin DSUB 1 m 182845 01 2 m 182845 02 3 m 182845 03 RS 485 422 DTE Serial Port The cRIO 9036 has an RS 485 422 DTE serial port that is...

Страница 11: ...E Serial Port Accessory Accessory Length Part Number RS 485 S8 Serial Cable 10 Position Modular Plug to 9 Pin DSUB Isolated 1 m 184428 01 Mini DisplayPort Use the Mini DisplayPort to connect a monitor...

Страница 12: ...rt Accessories Accessory Length Part Number Mini DisplayPort to Full DisplayPort Native Cable 0 5 m 157232 0R5 1 m 157232 01 2 m 157232 02 Mini DisplayPort to VGA Adapter Cable 0 5 m 157230 0R5 Mini D...

Страница 13: ...152166 02 Related Information File System on page 20 Installing a Ferrite on the USB Cables You must install a ferrite around all USB cables connected to the USB host ports to ensure that the cRIO 903...

Страница 14: ...s Caution Do not hot swap USB devices while the cRIO 9036 is in a hazardous location or connected to high voltages If the cRIO 9036 is not in a hazardous location you can connect and disconnect USB de...

Страница 15: ...to default settings 1 Hold the RESET button for 5 seconds and then release it to boot the controller in safe mode and enable Console Out 2 Hold the RESET button again for 5 seconds to boot the control...

Страница 16: ...RIO 9036 provides the following LEDs Figure 5 cRIO 9036 LEDs 5 4 1 2 3 6 1 POWER LED 2 STATUS LED 3 USER1 LED 4 USER FPGA1 LED 5 Gigabit Ethernet LEDs 6 SD LEDs POWER LED Indicators The following tabl...

Страница 17: ...to safe mode by pressing the reset button for longer than five seconds or by enabling safe mode in MAX Refer to the Measurement Automation Explorer MAX Help for information about safe mode Blinks four...

Страница 18: ...LED to help debug your application or retrieve application status Refer to the LabVIEW Help for information about programming this LED Ethernet LED Indicators The following table lists the Ethernet LE...

Страница 19: ...hile this LED is lit Chassis Grounding Screw The cRIO 9036 provides a chassis grounding screw Figure 6 cRIO 9036 Chassis Grounding Screw 1 1 Chassis Grounding Screw For EMC compliance you must connect...

Страница 20: ...y is dead The cRIO 9036 still starts but the system clock is reset to the date and time of the BIOS release The battery is not user replaceable If you need to replace the CMOS battery contact NI Refer...

Страница 21: ...e accessory requires tool access to the top right and bottom of the cRIO 9036 What to Use cRIO 9036 C Series modules Module Immobilization accessory kit 158533 01 Module immobilization bracket Install...

Страница 22: ...x T20 driver Tighten the screw to a maximum torque of 1 3 N m 11 5 lb in 5 Install the two M3 x 0 5 flat head screws from the accessory kit in the top and bottom of the cRIO 9036 using the appropriate...

Страница 23: ...5 mm DIN rail on a desktop or in a rack Mounting the cRIO 9036 in these or other configurations can reduce the maximum allowable ambient temperature and can affect the typical accuracy of modules in t...

Страница 24: ...226 6 mm 8 92 in 8 6 mm 0 34 in 88 1 mm 3 47 in Figure 10 cRIO 9036 Side Dimensions 53 4 mm 2 10 in 53 4 mm 2 10 in 53 4 mm 2 10 in 53 4 mm 2 10 in 44 0 mm 1 73 in 44 0 mm 1 73 in 44 0 mm 1 73 in 44...

Страница 25: ...quire different cabling clearances For a complete list of cabling clearances for C Series modules visit ni com info and enter the Info Code crioconn Figure 12 cRIO 9036 Cabling Clearance 29 1 mm 1 14...

Страница 26: ...e Directly on a Flat Surface For environments with high shock and vibration NI recommends mounting the cRIO 9036 directly on a flat rigid surface using the mounting holes in the cRIO 9036 What to Use...

Страница 27: ...of insertion into the cRIO 9036 Tighten the screws to a maximum torque of 1 3 N m 11 5 lb in Surface Mounting Dimensions The following figure shows the surface mounting dimensions for the cRIO 9036 Fi...

Страница 28: ...ounting plate to the cRIO 9036 using the screwdriver and M4 x 10 screws Tighten the screws to a maximum torque of 1 3 N m 11 5 lb in You must use the screws provided with the NI panel mounting kit bec...

Страница 29: ...2 mm 0 29 in 25 4 mm 1 00 in Mounting the cRIO 9036 on a DIN Rail You can use the NI DIN rail mounting kit to mount the cRIO 9036 on a standard 35 mm DIN rail What to Use cRIO 9036 Screwdriver Philli...

Страница 30: ...y are the correct depth and thread for the DIN rail clip Clipping the Device on a DIN Rail Complete the following steps to clip the cRIO 9036 on a DIN rail 1 2 1 Insert one edge of the DIN rail into t...

Страница 31: ...te You must use the NI DIN rail mounting kit 157268 01 in addition to a rack mounting kit Mounting the Device on a Desktop You can use the NI desktop mounting kit to mount the cRIO 9036 on a desktop W...

Страница 32: ...sions 2 17 2 mm 0 68 in 361 7 mm 14 24 in 39 1 mm 1 54 in Figure 17 cRIO 9036 Desktop Mounting Side Dimensions 132 8 mm 5 23 in 127 2 mm 5 01 in BIOS Configuration Resetting the System CMOS and BIOS S...

Страница 33: ...ation to CMOS BIOS Setup Utility Use the BIOS setup utility to change configuration settings and to enable special functions The cRIO 9036 ships with configuration settings that work for most applicat...

Страница 34: ...ation information BIOS Version and Build Date These values indicate the version of the controller BIOS and the date on which the BIOS was built Embedded Firmware Version This value identifies the buil...

Страница 35: ...ff the cRIO 9036 returns to the soft off power state after AC power is restored When set to Turn On the cRIO 9036 powers on when DC power is restored Power Button Off Behavior This setting specifies h...

Страница 36: ...e hub descriptor Device Power Up Delay in Seconds This setting specifies the number of seconds the POST waits for a USB device or hub to power on This setting is only visible when the Device Power Up...

Страница 37: ...urations to boot settings The factory default settings provide the most compatible and optimal configuration Setup Prompt Timeout This setting specifies the number of seconds the system waits for a BI...

Страница 38: ...to select this option Save Changes Changes made to BIOS settings during this session are committed to NVRAM The setup utility remains active allowing further changes Discard Changes Any changes made...

Страница 39: ...r s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification...

Страница 40: ...s EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and...

Отзывы: