Temperature Measurement Range

LSU 4.2............................................. 610 to 1060 °C
LSU 4.9............................................. 533 to 1200 °C

Resistance Measurement Resolution ........ 0.5 

Resistance Measurement Accuracy .......... ± 0.1 %
Temperature Control Target

LSU 4.2............................................. 750 °C
LSU 4.9............................................. 780 °C

Temperature Control Effective Heater
Voltage Range........................................... 5.0 to 13.0 V
Temperature Control PWM Frequency .... 100 Hz
Heater Fuse ............................................... Littelfuse part number 0451007.MRL 

(7 A, 125 V)

EGO Sensor

Measurement Range ................................. 0.0 to 1.36 V
Measurement Resolution .......................... 1 mV
Measurement Accuracy ............................ ± 0.1 %
Input Over-Voltage Protection.................. –15 to 44 V

Safety Guidelines

Caution

Do not operate the NI 9757 n a manner not specified in these operating 

instructions. Product misuse can result in a hazard. You can compromise the safety 
protection built into the product if the product is damaged in any way. If the product 
is damaged, return it to National Instruments for repair.

Compliance and Certifications

Safety

This product meets the requirements of the following standards of safety for electrical equipment 
for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment 
for measurement, control, and laboratory use:

EN 61326-1 (IEC 61326-1): Class A emissions; Industrial immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

AS/NZS CISPR 11: Group 1, Class A emissions

Содержание NI 9757

Страница 1: ...on 2 Pinout 2 Hardware 2 Powering the Module 3 Platform Compatibility 3 Bosch USA LSU 4 x Wide Band Oxygen Sensor Controllers 4 Narrow Band Oxygen Sensor Inputs 7 Physical Specifications and Character...

Страница 2: ...ble 4 Ch Narrow band sensor input differential All channel readings updated at 1 kHz LabVIEW FPGA and LabVIEW Real Time VIs for quick integration with application Pinout Figure 1 NI 9757 Pin Assignmen...

Страница 3: ...The module is reverse battery protected to 18 V Without sensors connected and enabled the NI 9757 requires up to 100 mA from the external supply The external power source must be capable of powering t...

Страница 4: ...Instruments recommends the NI 9214 for thermocouple measurements in CompactRIO systems using NI Powertrain Control modules Note NI Powertrain Control modules do not support Scan Interface mode auto d...

Страница 5: ...he associated sensor type is labeled next to the switch Caution Do not attempt to open the module housing or change the switch selection while the module is inserted in a chassis or externally connect...

Страница 6: ...te Sensor connector pin 2 does not actually have a green wire from the sensor to the sensor connector A calibration resistor feeds this connector pin within the sensor connector housing The color code...

Страница 7: ...r The two white wires connect to a resistive heater element inside the EGO sensor The NI 9757 does not provide connections for these wires Connect these to an external 12 V power source as shown in Fi...

Страница 8: ...Capacitance 300 F Inrush Current 3 A for 1 msec at 13 8 V Consumption No UEGO Sensors Enabled 1 3 W at 13 8 V 1 UEGO Sensor Enabled 15 W at 13 8 V 2 UEGO Sensors Enabled 30 W at 13 8 V Maximum Module...

Страница 9: ...a manner not specified in these operating instructions Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the...

Страница 10: ...EE EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers National Instruments WEEE initiatives and co...

Страница 11: ...mation at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPL...

Отзывы: