Physical Specifications and Characteristics

Weight ...............................................................145 g

Maximum Altitude............................................2000 m

Operating Temperature .....................................-40 °C to 70 °C

Maximum Ambient Temperature......................70 °C 

Operating Humidity ..........................................10% to 90% RH, noncondensing

Pollution Degree ...............................................2 

Ingress Protection .............................................IP40

For indoor use only.

If you need to clean the module, wipe it with a dry towel.

Safety Guidelines

Caution

Do not operate this module in a manner not specified in these operating 

instructions. Do not exceed the 60VDC rating. Product misuse can result in a hazard. 
You can compromise the safety protection built into the product if the product is 
damaged in any way. If the product is damaged, return it to National Instruments for 
repair.

Compliance and Certifications

Safety

This product meets the requirements of the following standards of safety for electrical equipment 
for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment 
for measurement, control, and laboratory use:

EN 61326-1 (IEC 61326-1): Class A emissions; Industrial immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

AS/NZS CISPR 11: Group 1, Class A emissions

Содержание NI 9752

Страница 1: ...ntroduction 2 Pinout 3 Hardware 3 Powering the Module 3 Platform Compatibility 4 Analog Inputs 4 VR Sensor Inputs 7 Hall Effect Sensor Inputs 9 Standard Circuit Configuration 10 Custom Configuration 12 Physical Specifications and Characteristics 12 Compliance and Certifications 12 ...

Страница 2: ...urable optional pull up pull down and divide resistors Anti aliasing filter per channel Dedicated 2 5 V precision reference 2 Ch VR sensor inputs 60 VDC input range Adaptive arming threshold 2 Ch Hall effect sensor or general purpose digital inputs Digital input with inverting Schmitt trigger hysteresis Short circuit protection Optional pull up pull down and divide resistors Analog filter for nois...

Страница 3: ...nnections Visit ni com info and enter Info Code ADCOMBO for more information on parts and accessories for the NI 9752 Powering the Module The NI 9752 requires power from the CompactRIO backplane male high density D SUB 15 pin HD15 connector which mates with the female HD15 connector on the module This power source provides a regulated 5 V and ground to various digital logic and analog functions wi...

Страница 4: ...with NI cRIO 911x NI cRIO 907x and NI R Series Expansion systems under the following conditions Leave one empty chassis slot between NI Powertrain Control modules and other NI modules Maintain an ambient system operating temperature of 0 C to 45 C Note Typical specifications of National Instruments modules might not apply when used in a system with NI Powertrain Control modules Note National Instr...

Страница 5: ...f channel configurations according to the circuits described below Figure 2 Unconfigured Generic Analog Input Circuit Schematic Divided Inputs Figure 3 shows the analog input circuit configuration for measuring voltages from 0 V to 33 V This is standard configuration for Channels 1 through 3 in the NI 9752 Channels with this configuration are protected from voltage swings of 50 V Figure 3 Analog I...

Страница 6: ...xamples of potentiometers are throttle position and pedal position sensors Figure 4 Analog Input Configuration for Active Sensors and Potentiometers Thermistor Inputs Switch Inputs Figure 5 shows the analog input circuit configuration for thermistors and switches to measure voltages from 0 V to 5 V This is standard configuration for Channels 17 through 21 in the NI 9752 Channels with this configur...

Страница 7: ...to toothed wheels as shown in Figures 6 and 7 The VR signal is positive when a tooth approaches the sensor tip and then rapidly swings back through zero precisely at the center of the tooth As the tooth moves away from the sensor tip the voltage continues in the negative direction and then returns to zero The polarity of the physical tooth or gap on the trigger wheel contributes to the polarity of...

Страница 8: ... on the NI 9752 The polarity of the sensor connection to the NI 9752 is critical Connect the leads of the sensor so that the positive input of the VR circuit receives the waveform shown in Figure 8 The waveform shown Figure 9 is incorrect and the VR circuit does not properly respond to this waveform The rapid zero crossing of the VR signal must be in the negative direction The physical center of e...

Страница 9: ...hreshold for a digital output to be generated at the rapid zero crossing The initial arming threshold is set to approximately 70 of the amplitude of each pulse Given a constant gap between the sensor and the trigger teeth the amplitude of a VR pulse is directly proportional to the speed of the trigger wheel For example if the VR amplitude at 1000 RPM is 10 V the amplitude at 2000 RPM is 20 V By us...

Страница 10: ...The NI 9752 comes with a standard configuration as illustrated in Table 1 below Table 1 Standard Analog Configuration Channel Pull up Resistor Pull down Resistor Divide Resistor Break Frequency Intended Use 1 open 1 kΩ 5 6 k 200 Hz 33 V Measurement 2 open 1 kΩ 5 6 k 200 Hz 33 V Measurement 3 open 1 kΩ 5 6 kΩ 200 Hz 33 V Measurement 4 open 51 kΩ 0 Ω 500 Hz Active Pot 5 open 51 kΩ 0 Ω 500 Hz Active ...

Страница 11: ...r Switch 20 1 kΩ open 0 Ω 500 Hz Thermistor Switch 21 1 kΩ open 0 Ω 500 Hz Thermistor Switch 22 2 5 V 0 2 Precision Reference Table 2 Standard VR Configuration Channel VR Amplitude Voltage 1 60 VDC 2 60 VDC Table 3 Standard Hall Configuration Channel Pull up Resistor Pull down Resistor Divide Resistor Break Frequency Intended Use 1 4 7 kΩ open 0 Ω 150 kHz Hall Proximity Switch or TTL 2 4 7 kΩ open...

Страница 12: ... not exceed the 60VDC rating Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is damaged return it to National Instruments for repair Compliance and Certifications Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement control an...

Страница 13: ...ducts in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the Minimize Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other...

Отзывы: