National Instruments NI 9469 Скачать руководство пользователя страница 28

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch

office websites, which provide up-to-date contact information,
support phone numbers, email addresses, and current events.

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for information on

National Instruments trademarks. Other product and company names mentioned herein are
trademarks or trade names of their respective companies. For patents covering National
Instruments products/technology, refer to the appropriate location: 

Help

»

Patents

 in your software,

the 

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/

patents

. You can find information about end-user license agreements (EULAs) and third-party

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information

 at

ni.com/legal/export-compliance

 for the National Instruments global trade compliance policy

and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO
EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION
CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government
Customers: The data contained in this manual was developed at private expense and is subject to
the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR
252.227-7014, and DFAR 252.227-7015.

© 2012—2015 National Instruments. All rights reserved.

373337B-01

May15

Содержание NI 9469

Страница 1: ...GETTING STARTED GUIDE NI 9469 Synchronization Module Fran ais Deutsch ni com manuals This document explains how to connect to the NI 9469...

Страница 2: ...ystem to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9469 only as described in this document Hot Surface This icon denotes that the component may be hot...

Страница 3: ...onment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhaza...

Страница 4: ...Gas Group IIC hazardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 Ex IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment Caution You must make sure that tran...

Страница 5: ...intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in r...

Страница 6: ...product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install...

Страница 7: ...469 has three RJ45 connectors on the front panel labeled Port 0 1 and 2 These connectors use standard straight through CAT 5e Ethernet cabling to provide connection to other NI 9469 modules only Each...

Страница 8: ...e crosspoint switch is not a full routing matrix You can connect only the same Line or Trig number For example Line 0 to Trig 0 but not Line 0 to Trig 2 However you can route clock signals on only Lin...

Страница 9: ...Line 0 Line 1 Line 2 Line 3 Line 0 Line 1 Line 2 Line 3 Line 0 Line 1 Line 2 Line 3 Trig 0 Trig 1 Trig 2 Trig 3 Clk Gen Sources Port 0 Port 1 Port 2 Backplane Onboard Destinations Port 0 Port 1 Port 2...

Страница 10: ...nected with a tree topology Figure 2 shows a tree topology example More advanced and customizable options create a flexible topological network of NI 9469 modules Refer to the Topologies section for e...

Страница 11: ...example If maximum separation distance is required connect the modules using a daisy chain topology with maximum cable length per hop as shown in Figure 4 Refer to the Cable section for information a...

Страница 12: ...y Out In Out Out In Out Out In Out Out In Out Out Out In Out In Out In Out Out Master Chassis 1 Slave Chassis 5 Slave Chassis 2 Slave Chassis 6 Slave Chassis 7 Slave Chassis 4 Slave Chassis 3 12 ni co...

Страница 13: ...ut In Out Out In In Out Out In Out Out In Out Out Out Out In In Out Out Slave Master Slave Chassis 1 Slave Chassis 3 Slave Chassis 4 Slave Chassis 6 Slave Chassis 5 Slave Chassis 7 Slave Chassis 2 NI...

Страница 14: ...ain Topology In Out Out In Out Out In Out Out In Out Out In Out Out In Out Out Master Chassis 1 Slave Chassis 2 Slave Chassis 3 Slave Chassis 4 Slave Chassis 5 Slave Chassis 6 14 ni com NI 9469 Gettin...

Страница 15: ...t In Out Out Out Out In In Out Out In Out Out In Out Out In Out Out Master Slave Chassis 1 Slave Slave Chassis 5 Slave Chassis 2 Slave Chassis 3 Slave Chassis 4 Slave Chassis 7 Slave Chassis 8 Slave C...

Страница 16: ...for information about support for sleep mode If the chassis supports sleep mode refer to the software help for information about enabling sleep mode Visit ni com info and enter cseriesdoc for informat...

Страница 17: ...ons The following specifications are typical for the range 40 C to 70 C unless otherwise noted I O Characteristics Front panel connectors Shielded RJ45 receptacle Front panel indicators 4 green LEDs N...

Страница 18: ...12 8 MHz or 13 1072 MHz Accuracy 3 5 ppm typical Cable Type1 CAT 5e Shielded Twisted Pair straight through Maximum propagation delay2 4 98 ns m Maximum length 100 m 1 Refer to the I O Characteristics...

Страница 19: ...Thermal dissipation at 70 C Active mode 1 W max Sleep mode 25 W Physical Characteristics To clean the module wipe it with a dry towel Weight 148 g 5 2 oz Safety Voltages Isolation Channel to channel N...

Страница 20: ...ontrol and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA 61010 1 EN 60079 0 2012 EN 60079 15 2010 IEC 60079 0 Ed 6 IEC 60079 15 Ed 4 UL 60079 0 Ed 5 UL 60079 15 Ed 3 CSA 60079 0 2011 CSA 60079...

Страница 21: ...Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Industrial...

Страница 22: ...tended for use only in heavy industrial locations Note Group 1 equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentionally generate radio frequency energy for...

Страница 23: ...Potentially Explosive Atmospheres ATEX Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To obtain product certifications...

Страница 24: ...Hz Operating shock IEC 60068 2 27 30 g 11 ms half sine 50 g 3 ms half sine 18 shocks at 6 orientations Environmental Refer to the manual for the chassis you are using for more information about meeti...

Страница 25: ...vironmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental informa...

Страница 26: ...sit ni com environment weee RoHS National Instruments RoHS National Instruments RoHS ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china World...

Страница 27: ...of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product...

Страница 28: ...Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Informatio...

Отзывы: