background image

© 2008 National Instruments Corp. All rights reserved.

372617A-01

Jul08

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the 

Terms of Use

 section on

ni.com/legal

 for more information about National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. 
For patents covering National Instruments products, refer to the appropriate location: 

Help»Patents

 in your software, 

the 

patents.txt

 file on your media, or 

ni.com/patents

.

Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, 
Malaysia 1800 887710, Mexico 01 800 010 0793, 
Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, 
Norway 47 (0) 66 90 76 60, Poland 48 22 3390150, 
Portugal 351 210 311 210, Russia 7 495 783 6851, 
Singapore 1800 226 5886, Slovenia 386 3 425 42 00, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, 
Taiwan 886 02 2377 2222, Thailand 662 278 6777, 
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545

Содержание NI 9403E

Страница 1: ...OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9403E 32 Channel TTL Digital Input Output Module...

Страница 2: ...r information about installing configuring and programming the system refer to the system documentation Visit ni com info and enter cseriesdoc for information about C Series documentation Caution Nati...

Страница 3: ...403E Operating Instructions and Specifications NI 9403E Dimensions The following figure shows the dimensions of the NI 9403E Figure 1 NI 9403E Dimensions in Millimeters Inches 73 4 2 89 0 0 0 00 26 7...

Страница 4: ...ital input output channels Figure 2 NI 9403E Pin Assignments DIO16 DIO17 DIO18 DIO19 DIO20 DIO21 DIO22 DIO23 COM COM DIO24 DIO25 DIO26 DIO27 DIO28 DIO29 DIO30 DIO31 DIO0 DIO1 DIO2 DIO3 DIO4 DIO5 DIO6...

Страница 5: ...e for input or output The DIO channels have Schmitt trigger inputs and are compatible with 5 V TTL logic devices Each input channel has hysteresis for improved performance with noisy and non monotonic...

Страница 6: ...i com Refer to Figure 3 for an illustration of several types of digital devices connected to the NI 9403E Figure 3 Connecting Digital Devices to the NI 9403E TTL Signal 5 V 5 V LED DIO0 as Input DIO1...

Страница 7: ...input data to the software After the protection period the NI 9403E automatically recovers to the latest direction configuration and output state If the overcurrent condition still exists the module...

Страница 8: ...ower and may dissipate less heat than it does in normal mode Refer to the Specifications section for more information about power consumption and thermal dissipation Specifications The following speci...

Страница 9: ...2 V min Output High VOH 5 2 V max Sourcing 100 A 4 75 V min Sourcing 2 mA 4 4 V min Low VOL Sinking 100 A 0 1 V max Sinking 2 mA 0 26 V max Input current 0 V Vin 4 5 V 250 A max Module output current...

Страница 10: ...amount of time input signals must be stable before reading from the module 2 Hold time is the amount of time input signals must be stable after initiating a read from the module 3 Propagation delay is...

Страница 11: ...x Direction change time1 18 S max Overvoltage protection Channel to COM 30 V max on up to 8 channels at a time however continued use at this level will degrade the life of the module 1 The update tran...

Страница 12: ...ethod 1 Case 3 Limited Part Stress Method Note Contact NI for Bellcore MTBF specifications at other temperatures or for MIL HDBK 217F specifications Power Requirements Power consumption from chassis A...

Страница 13: ...dry towel Weight 47 g 1 7 oz Safety Safety Voltages Connect only voltages that are within the following limits Channel to COM 30 V max on up to 8 channels at a time Measurement Category I Isolation C...

Страница 14: ...lude signal levels special equipment limited energy parts of equipment circuits powered by regulated low voltage sources and electronics Caution Do not connect the NI 9403E to signals or use for measu...

Страница 15: ...lick the appropriate link in the Certification column Environmental National Instruments C Series modules are intended for indoor use only but may be used outdoors if installed in a suitable enclosure...

Страница 16: ...responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to...

Страница 17: ...he life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers and National Instruments WEEE initiatives visit ni com environment weee RoHS Nation...

Страница 18: ...nal Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the cal...

Страница 19: ...nts products refer to the appropriate location Help Patents in your software the patents txt file on your media or ni com patents Korea 82 02 3451 3400 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Me...

Отзывы: