Signals
The NI 9242 has three AI terminals and a Neutral terminal. You
can connect three-phase and single-phase measurement
configurations to the NI 9242. The NI 9242 supports standard
service levels up to 250 V
rms
Line-to-Neutral (L-N) and 400 V
rms
Line-to-Line (L-L). You can also connect standard potential
transformers to the NI 9242.
Note
You must use 2-wire ferrules to create a secure
connection when connecting more than one wire to a
single terminal on the NI 9242.
Circuitry
Each channel on the NI 9242 provides an independent signal path
and ADC. Each terminal has the same input impedance to ground.
The NI 9242 returns the voltage between each AI terminal and the
Neutral terminal as well as the voltage between the Neutral
terminal and the chassis ground. Refer to Figure 6 for a diagram of
the equivalent voltages the module returns.