background image

NI corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI
also has offices located around the world. For telephone support
in the United States, create your service request at 

ni.com/support

or dial 1 866 ASK MYNI (275 6964). For telephone support
outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which

provide up-to-date contact information, support phone numbers,
email addresses, and current events.

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for information on NI

trademarks. Other product and company names mentioned herein are trademarks or trade names
of their respective companies. For patents covering NI products/technology, refer to the
appropriate location: 

Help

»

Patents

 in your software, the 

patents.txt

 file on your media, or the

National Instruments Patent Notice

 at 

ni.com/patents

. You can find information about end-user

license agreements (EULAs) and third-party legal notices in the readme file for your NI product.
Refer to the 

Export Compliance Information

 at 

ni.com/legal/export-compliance

 for the NI

global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/
export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF
THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.
U.S. Government Customers: The data contained in this manual was developed at private
expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR
52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2008—2015 National Instruments. All rights reserved.

374238H-01

Oct15

Содержание NI 9234

Страница 1: ...GETTING STARTED GUIDE NI 9234 4 AI 5 V 24 Bit 51 2 kS s ch Simultaneous AC DC Coupling IEPE AC Coupling...

Страница 2: ...Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9234 only as described in this document Cauti...

Страница 3: ...referred to as MAINS voltage MAINS is a hazardous live electrical supply system that powers equipment This category is for measurements of voltages from specially protected secondary circuits Such vol...

Страница 4: ...hese guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Caution Do not r...

Страница 5: ...arked II 3G and is suitable for use in Zone 2 hazardous locations in ambient temperatures of 40 C Ta 70 C If you are using the NI 9234 in Gas Group IIC hazardous locations you must use the device in a...

Страница 6: ...he product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment...

Страница 7: ...board applications To verify Lloyd s Register certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In o...

Страница 8: ...ications Operating temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 5 000 m Indoor use only Note...

Страница 9: ...g the NI 9234 The NI 9234 provides connections to four simultaneously sampled analog input channels Figure 1 NI 9234 Pinout AI3 AI3 AI2 AI2 AI0 AI0 AI1 AI1 NI 9234 Getting Started Guide National Instr...

Страница 10: ...t with each other the modules or the chassis Signal Descriptions Table 1 Signal Descriptions Signal Signal Description AI Provides DC excitation when enabled and positive input signal connection AI Pr...

Страница 11: ...erential Signals You can connect floating differential signals to the NI 9234 Figure 2 Connecting Floating Differential Signals to the NI 9234 NI 9234 AI AI Signal Source NI 9234 Getting Started Guide...

Страница 12: ...34 NI 9234 AI AI Signal Source Common Voltage Mode Make sure the voltage on the AI shell is in the common mode range to ensure proper operation of the NI 9234 The AI shell is protected against acciden...

Страница 13: ...es an error that is dependent on the AI lead impedance This error is approximately 50 ppm of range and 15 ppm of reading per ohm of AI impedance The common mode bias current causes an error only with...

Страница 14: ...to measure ground referenced or floating IEPE sensors Typical IEPE sensors have a case that is electrically isolated from the IEPE electronics so connecting the sensor to the NI 9234 results in a floa...

Страница 15: ...on The NI 9234 provides overvoltage protection for each channel Note Refer to the device datasheet on ni com manuals for more information about overvoltage protection NI 9234 Getting Started Guide Nat...

Страница 16: ...tware CompactRIO NI CompactDAQ RELATED INFORMATION C Series Documentation Resources ni com info cseriesdoc Services ni com services NI 9234 Datasheet NI RIO Help LabVIEW FPGA Help NI 9234 Datasheet NI...

Страница 17: ...duct Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council o...

Страница 18: ...cts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information a...

Отзывы: