BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Standard Multi-Transmission Unit ...................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    85 – 132V AC rating:  85 – 132V, 47 – 66 Hz, 

  

approx. 17.5VA (max.)

    170 – 264V AC rating:  170 – 264V, 47 – 66 Hz,  

 

approx. 17.5VA (max.)

    24V DC rating: 24V ±10%, approx. 17W (max.)
    12V DC rating: 12V ±10%, approx. 17W (max.)

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal and output signal for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +50°C 

(23 to 122°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

STANDARD MULTI-TRANSMISSION UNIT

MODEL

DLA1

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-6510  Rev.1  P. 1 / 14

INSTRUCTION MANUAL

Содержание DLA1

Страница 1: ...move the unit or mount it turn off the power supply and input signal and output signal for safety ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit insi...

Страница 2: ...FICATION Power LED Indicator RUN LED Indicator Fiber Link Connector Station Address Setting Rotary Switches SA1 SA2 Specifications I O Terminal Release Tab RUN Output Terminating Resistor Power Supply...

Страница 3: ...with the switch and the number plus 1 Do not use this following number for other units Input only Unit SA 40H Output only Unit SA 40H Example 4 SA1 0 SA2 4 SA1 0 SA2 2 2 Paired Units Input Output Inp...

Страница 4: ...ctive covers over the FIBER LINK terminals and connect FIBER LINK connectors Observe appropriate radiuses when bending fiber optic ca bles Follow cable manufacturer s installation procedures Fiber bre...

Страница 5: ...units inside twisted pair cable loops Example Remove Keep Keep Keep Keep MOUNTING REQUIREMENTS unit mm inch 55 2 17 55 2 17 288 11 34 2 M4 SCREW 3 5 14 SURFACE MOUNTING SIDE MOUNTING terminal block at...

Страница 6: ...Type Connector Terminals 9 8 7 6 5 4 3 2 1 Not provided for fiber optics code 2 Note There is no specific order for connecting fiber optics PIN TERMINAL PHOENIX CONTACT AI 1 5 8BK RECOMMENDED MULTI S...

Страница 7: ...1 CN2 U L LED Indicator Selector Euro Type Euro Type Euro Type TRANSMISSION POWER CONNECTION DIAGRAM 6 7 8 9 V EARTH FG U POWER RUN CONTACT OUTPUT 2 1 5 4 3 JUMPER PIN TWISTED PAIR CABLE transmission...

Страница 8: ...dimensions See Figure B 1 CONNECTOR PIN ASSIGNMENT INPUT CONNECTOR CN1 CONNECTOR CN2 PIN NO CH NO PIN NO CH NO PIN NO CH NO PIN NO CH NO A1 Di 1 B1 Di17 A1 Di33 B1 Di49 2 2 2 18 2 34 2 50 3 3 3 19 3...

Страница 9: ...signment See Figure A 2 Model DLA1 xC2 FRONT PANEL OUTPUT 40 pin Connector Terminal Block Contact Output Indicator LED External dimensions See Figure A 1 CONNECTION DIAGRAM OUTPUT 1 2 3 4 5 6 7 8 9 10...

Страница 10: ...t See Figure B 2 Model DLA1 xC4 FRONT PANEL OUTPUT Contact Output Indicator LED CN2 LED Indicator Selector CN1 U L SW External dimensions See Figure B 1 CONNECTOR PIN ASSIGNMENT OUTPUT CONNECTOR CN1 C...

Страница 11: ...signment See Figure A 2 Model DLA1 xE2 FRONT PANEL I O 40 pin Connector Terminal Block Contact I O Indicator LED External dimensions See Figure A 1 CONNECTION DIAGRAM I O 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 12: ...signment See Figure A 2 Model DLA1 xM1 FRONT PANEL OUTPUT 40 pin Connector Terminal Block Modular Jack Output CPU RUN Indicator External dimensions See Figure A 1 CONNECTION DIAGRAM OUTPUT 1 2 3 4 5 6...

Страница 13: ...not use Terminal assignment See Figure A 2 Model DLA1 xR1 FRONT PANEL I O 40 pin Connector Terminal Block Modular Jack I O CPU RUN Indicator External dimensions See Figure A 1 CONNECTION DIAGRAM I O 1...

Страница 14: ...Output CPU RUN Indicator Pulse Output Indicator LED External dimensions See Figure A 1 CONNECTION DIAGRAM OUTPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32...

Отзывы: