Specifications
Fiber-Optic MXI-Express x4 for PXI Express User Manual
A-4
ni.com
NI PCIe-8375
Maximum altitude...................................2,000 m (at 25 °C ambient
temperature)
Pollution Degree .....................................2
Indoor use only
Operating Environment
Ambient temperature range ....................0 to 55 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range..........................10 to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Storage Environment
Ambient temperature range ....................–20 to 70 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range..........................5 to 95%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Caution
Clean the NI PXIe-8375 and NI PCIe-8375 with a soft nonmetallic brush. Make
sure that the device is completely dry and free from contaminants before returning it to
service.
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or the
section.