Your system is fully operational if the sequence finishes without error and you can display a
3D antenna pattern from the antenna. To verify the accuracy of the test, refer to
Tip
NI recommends familiarizing yourself with the example sequences. When you
save the example sequence as a new file, you must also save the CSV file with the
same file name so the sequence file can load it correctly.
Related Information
mmWave OTA Test Positioner SFP
on page 25
Software Reference
Soft Front Panels
mmWave OTA Test Positioner SFP
The mmWave OTA Test Positioner SFP allows you to quickly manipulate the positioner.
You can complete the following tasks with the mmWave OTA Test Positioner SFP:
•
Move the azimuth or elevation independently
•
Configure a sweep in both azimuth and elevation
•
Configure the Absolute Zero location of the positioner for antenna alignment
You can access the mmWave OTA Test Positioner SFP at
Start
»
All Programs
»
National
Instruments
»
OTA Test
»
Positioner
»
mmWave OTA Test Positioner SFP
.
mmWave OTA Validation Test Reference Architecture
|
© National Instruments
|