B-36
|
ni.com
Appendix B
Timing Diagrams
Gate Pulse Width
Figure B-47 and Table B-31 show the timing requirements for Counter
n
Gate. The requirements
depend on the gating mode.
Figure B-47.
Counter n Gate Pulse Width Timing Diagram
Gate to Source Setup and Hold
The counter can be modeled as a set of flip flops where the D input is Count Enable and the clock
input is Selected Source, as shown in Figure B-41. This section shows the setup and hold
requirements for two different cases:
•
A PFI pin drives Counter
n
Source and a different PFI pin drives Counter
n
Gate
•
The general case (all other combinations of signals driving Source and Gate)
t
6
Counter
n
Source Pulse
Width
80 MHz Source
6.2
—
Other Internal
Source
12.5
—
External Source
16.0
—
*
The times in this table are measured at the pin of the M Series device. For example, t
5
specifies the
minimum period of a signal driving a PFI, RTSI, or PXI_STAR pin when that signal is internally routed
to Counter
n
Source.
Table B-31.
Counter n Gate Pulse Width Timing
Time
Description
Gating Mode
Min (ns)
*
Max (ns)
t
7
Counter
n
Gate Pulse
Width
Edge
12.0
—
Counter
n
Gate Pulse
Width
Level
One Source Period
—
*
The times in this table are measured at the pin of the M Series device. That is, t
7
specifies the minimum
pulse width of a signal driving a PFI, RTSI, or PXI_STAR pin when that signal is internally routed to
Counter
n
Gate.
Table B-30.
Counter n Source Timing (Continued)
Time
Description
Synchronization
Mode
Min (ns)
*
Max (ns)
Counter n Gate
t
7
t
7
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com